Strona 1 - SUPER

® SUPERUSER'S MANUALRevision 1.0SUPERSERVER®2028TP-HC1R2028TP-HC1TR2028TP-HC1FR

Strona 2

xNotesSUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL

Strona 3 - Manual Organization

7-6SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALCPU CongurationThis submenu displays the following CPU information as detected by the BIOS.

Strona 4

Chapter 7: BIOS7-7Hardware Prefetcher (Available when supported by the CPU)If set to Enable, the hardware prefetcher will prefetch streams of data and

Strona 5

7-8SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALX2 APIC (Advanced Programmable Interrupt Controller)Based on Intel's Hyper-Threading arc

Strona 6 - Table of Contents

Chapter 7: BIOS7-9P-state CoordinationThis feature is used to change the P-state (Power-Performance State) coordi-nation type. P-state is also known a

Strona 7 - Chapter 3 System Interface

7-10SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALChipset CongurationWarning! Please set the correct settings for the items below. A wro

Strona 8

Chapter 7: BIOS7-11IOU0 (II0 PCIe Port 2)This item congures the PCI-E port Bifuraction setting for a PCI-E port specied by the user. The options are

Strona 9 - Chapter 7 BIOS

7-12SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL Intel VT for Directed I/O (VT-d)Intel VT for Direct I/O (VT-d)Intel® VT for Directed I/O (

Strona 10

Chapter 7: BIOS7-13Link Speed ModeUse this item to select the data transfer speed for QPI Link connections. The options are Fast and Slow.Link Frequen

Strona 11 - Introduction

7-14SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALData ScramblingSelect Enabled to enable data scrambling to enhance system performance and d

Strona 12 - 1-2 Serverboard Features

Chapter 7: BIOS7-15the same set of operations in parallel to boost performance. The options are Disable, Mirror, and Lockstep Mode. Lockstep x4 DIMMs

Strona 13 - Other Features

Chapter 1 Introduction1-1 OverviewThe SuperServer 2028TP-HC1R/HC1TR/HC1FR is a high-end server comprised of two main subsystems: the SC217HQ+-R2K02B

Strona 14 - 1-3 Server Chassis Features

7-16SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALSouth BridgeThe following South Bridge information will display:USB Conguration•USB Modu

Strona 15 - FAN SPEED

Chapter 7: BIOS7-17EHCI2Select Enabled to enable EHCI (Enhanced Host Controller Interface) support on USB 2.0 connector #2 (-at least one USB 2.0 conn

Strona 16 - 1-5 Contacting Supermicro

7-18SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALSATA CongurationWhen this submenu is selected, AMI BIOS automatically detects the presence

Strona 17 - : System Notes

Chapter 7: BIOS7-19Port 0 ~ Port 5 SATA Device TypeUse this item to specify if the SATA port specied by the user should be con-nected to a Sol

Strona 18

7-20SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALPort 0 ~ Port 5 Hot PlugSelect Enabled to enable hot-plugging support for a port specied by

Strona 19 - Server Installation

Chapter 7: BIOS7-21•Software Preserve Support sSATA Port 0~ Port 3Select Enabled to enable an sSATA port specied by the user. The options are Disabl

Strona 20 - 2-4 Warnings and Precautions

7-22SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALsSATA RAID Option ROM/UEFI DriverSelect EFI to load the EFI driver for system boot. Select L

Strona 21 - Rack Mounting Considerations

Chapter 7: BIOS7-23•ME Firmware Status #2•Current State•Error CodePCIe/PCI/PnP CongurationThe following PCI information will be displayed:•PCI B

Strona 22

7-24SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALMaximum Read RequestSelect Auto for the system BIOS to automatically set the maximum size fo

Strona 23

Chapter 7: BIOS7-25Network StackSelect Enabled to enable PXE (Preboot Execution Environment) or UEFI (Uni-ed Extensible Firmware Interface) for

Strona 24

1-2SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL1-2 Serverboard FeaturesAt the heart of the SuperServer 2028TP-HC1R/HC1TR/HC1FR lies the X10

Strona 25

7-26SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL*If the item above set to Enabled, the following items will become available fo

Strona 26 - Standard Chassis Installation

Chapter 7: BIOS7-27VT-UTF8 Combo Key SupportSelect Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Enabled

Strona 27 - System Interface

7-28SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALSOL/COM2 Console Redirection SettingsUse this feature to specify how the host computer will

Strona 28 - 3-3 Control Panel LEDs

Chapter 7: BIOS7-29VT-UTF8 Combo Key SupportSelect Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Enabled

Strona 29 - 3-4 Hard Drive Carrier LEDs

7-30SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALEMS Console Redirection Settings (Available when EMS Console Redirection is enabled)Use thi

Strona 30

Chapter 7: BIOS7-31port to enhance data integrity and network security. Please reboot the system for a change on this setting to take effect. The opti

Strona 31 - Chapter 4

7-32SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL7-4 Event LogsUse this feature to congure Event Log settings.Change SMBIOS Event Log Set

Strona 32

Chapter 7: BIOS7-33Erasing SettingsErase Event LogSelect Yes to erase all error events in the SMBIOS (System Management BIOS) log before an event logg

Strona 33

7-34SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL7-5 IPMIUse this feature to congure Intelligent Platform Management Interface (I

Strona 34 - Installation Instructions

Chapter 7: BIOS7-35When SEL is FullThis feature allows the user to determine what the AMI BIOS should do when the system event log is full. Select Era

Strona 35 - 250 V, 20 A

1-3Chapter 1: IntroductionPCI Expansion SlotsThe SuperServer 2028TP-HC1R/HC1TR/HC1FR has for each node one (1) PCI Express 3.0 x16 slot (Slot 1) avail

Strona 36 - Power Disconnection Warning

7-36SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL7-6 Security SettingsThis menu allows the user to congure the following security

Strona 37 - ילמשח קותינ ינפמ הרהזא

Chapter 7: BIOS7-377-7 Boot SettingsUse this feature to congure Boot Settings:Boot CongurationSetup Prompt TimeoutUse this item to indicate how man

Strona 38 - Equipment Installation

7-38SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL•Dual Boot Order #7•Dual Boot Order #8•Dual Boot Order #9•Dual Boot Order #10•Dual Boot

Strona 39 - Restricted Area

Chapter 7: BIOS7-397-8 Save & ExitSelect the Save & Exit tab from the BIOS setup screen to congure the settings below.Discard Chang

Strona 40 - Battery Handling

7-40SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALRestore DefaultsSelect this item and press <Enter> to load the manufacture default set

Strona 41 - 

A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time th

Strona 42 - Redundant Power Supplies

A-2SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALNotes

Strona 43 - Backplane Voltage

B-1Appendix B: System SpecicationsAppendix B System SpecicationsNote: Unless noted specications apply to a complete system (all serverboards).Pro

Strona 44

B-2SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALChassisSC217HQ+-R2K02B (2U rackmount) Dimensions: (WxHxD) 17.25 x 3.47 x 28.5 in. (438 x 88 x

Strona 45 - יצראה למשחה יקוח םואית

B-3Appendix B: System SpecicationsNotes

Strona 46 - Hot Swap Fan Warning

1-4SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL1-3 Server Chassis FeaturesThe following is a general outline of the main features of the SC

Strona 47 - 

B-4SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL(continued from front)The products sold by Supermicro are not intended for and will not be us

Strona 48 - Power Cable and AC Adapter

1-5Chapter 1: IntroductionFigure 1-1. Intel PCH C612 Chipset: System Block DiagramNote: This is a general block diagram and may not exactly repre-sen

Strona 49 - (UL/CSA  )

1-6SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL1-5 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jos

Strona 50

1-7Chapter 1: Introduction1-6 2U Twin2: System NotesAs a 2U Twin2 conguration, the SuperServer 2028TP-HC1R/HC1TR/HC1FR is a unique server system. Wi

Strona 51 - Advanced Serverboard Setup

1-8SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALNotes

Strona 52 - 5-2 Connecting Cables

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 2028

Strona 53 - 5-3 Rear I/O Ports

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu

Strona 54 - OPEN 1st

2-2SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALChoosing a Setup Location•Leave enough clearance in front of the rack to enable you to open

Strona 55 - IMPORTANT!

Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am

Strona 56

2-4SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL2-5 Installing the System into a RackThis section provides information on installing the 202

Strona 57

Chapter 2: Server Installation2-5Figure 2-2. Extending and Releasing the Inner RailLocking TabsEach inner rail has a locking tab. This tab locks the c

Strona 58

2-6SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALFigure 2-3. Installing the Inner Rails Installing The Inner Rails on the ChassisTo install th

Strona 59 - 5-5 Installing Memory

Chapter 2: Server Installation2-7Figure 2-5. Extending and Releasing the Outer Rails1112131421D01L-min=676.00(26.61")(outer rail)Installing the O

Strona 60 - DIMM slots

2-8SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALFigure 2-6. Installing into a RackBall-Bearing ShuttleStandard Chassis InstallationInstalling

Strona 61

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel and on the drive carriers to keep yo

Strona 62 - Rev. 1.02

SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL3-23-2 Control Panel ButtonAlertThis LED is illuminated when an alert condition occurs.•A soli

Strona 63

Chapter 3: System Interface3-3•A ashing red light which ashes in four second interfals indicates a power failure. When notied of an al

Strona 64 - 5-8 Connector Denitions

iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta

Strona 65 - 4 No Connection

SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL3-4Notes

Strona 66

4-1Chapter 4: Warning Statements for AC SystemsChapter 4 Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe

Strona 67 - Pins 2-3 Disabled

4-2SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie benden sich in

Strona 68

4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기

Strona 69 - (X8ST3-F)

4-4SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALInstallation Instructions Warning!Read the installation instructions before connecting the sy

Strona 70

4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over

Strona 71

4-6SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALPower Disconnection Warning Warning!The system must be disconnected from all sources of power

Strona 72 - 5-12 Installing Software

4-7Chapter 4: Warning Statements for AC SystemsWarnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt sein, das von

Strona 73 - SuperDoctor® 5

4-8SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALEquipment Installation Warning!Only trained and qualied personnel should be allowed to insta

Strona 74 - 5-13 Onboard Battery

4-9Chapter 4: Warning Statements for AC SystemsRestricted Area Warning!This unit is intended for installation in restricted access areas. A restricted

Strona 75 - Advanced Chassis Setup

SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALivChapter 6: Advanced Chassis SetupRefer to Chapter 6 for detailed information on the SC217HQ+-R

Strona 76 - 6-2 Control Panel

4-10SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALBattery Handling Warning!There is the danger of explosion if the battery is replaced incorre

Strona 77 - 6-3 Chassis Cover

4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur

Strona 78 - 6-4 Air Shrouds

4-12SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALRedundant Power Supplies Warning!This unit might have more than one power supply connection.

Strona 79 - 6-6 System Fans

4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltage Warning!Hazardous voltage or energy is present on the backplane when the system is o

Strona 80

4-14SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALComply with Local and National Electrical Codes Warning!Installation of the equipment must c

Strona 81

4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national

Strona 82 - Removing the Backplane

4-16SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALWarnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Land

Strona 83

4-17Chapter 4: Warning Statements for AC Systems!הרהזא יקלח תא םיריסמ רשאכ שי .םידבוע ןיידע םיררוואמהו ןכתי ,זראמהמ ררוואמה קיחרהללררוואמה ךותב םיחתפ

Strona 84 - Installing the Backplane

4-18SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALPower Cable and AC Adapter Warning!When installing the product, use the provided or designa

Strona 85 - I/O Shield

4-19Chapter 4: Warning Statements for AC Systems¡Advertencia! Al instalar el producto, utilice los cables de conexión previstos o designados, los cabl

Strona 86

vSUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALNotes

Strona 87

4-20SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALWaarschuwing Bij het installeren van het product, gebruik de meegeleverde of aangewezen kabe

Strona 88 - 6-9 Adapter Card Replacement

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X10DRT-P/PT/PIBF s

Strona 89 - Installing the Riser Card

5-2SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL5-2 Connecting CablesNow that the processors are installed, the next step is to connect the

Strona 90 - Expansion Card

Chapter 5: Advanced Serverboard Setup5-35-3 Rear I/O PortsSee Figure 5-1 below for the and locations of the various rear I/O ports and the UID switch

Strona 91 - Accessing the Drive Bays

5-4SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL5-4 Processor and Heatsink InstallationNotes: •Always remove the power cord before adding,

Strona 92

Chapter 5: Advanced Serverboard Setup5-53. With the second lever fully retracted, gently push down on the "Open 1st" lever to loosen the lo

Strona 93 - Hard Drive Carrier

5-6SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL8. Make sure the locking mechanism on the "Close 1st" lever catches the lip of the

Strona 94 - 6-11 Power Supply

Chapter 5: Advanced Serverboard Setup5-7Installing a Passive CPU Heatsink1. Do not apply any thermal grease to the heatsink or the CPU die -- the req

Strona 95 - Chapter 7

5-8SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALRemoving the HeatsinkCaution: We DO NOT recommend that the CPU or the heatsink be removed. Ho

Strona 96 - 7-2 Main Setup

Chapter 5: Advanced Serverboard Setup5-95-5 Installing MemoryInstalling Memory1. Insert each memory module vertically into its slot, paying attentio

Strona 97

viTable of ContentsChapter 1 Introduction1-1 Overview ...

Strona 98 - Boot Feature

5-10SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALProcessor & Memory Module Population CongurationFor the memory to work properly, follow

Strona 99 - Power Conguration

Chapter 5: Advanced Serverboard Setup5-115-6 Adding PCI Expansion CardsThe 2028TP-HC1R/HC1TR/HC1FR includes one preinstalled riser card per node, des

Strona 100 - CPU Conguration

5-12SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL5-7 Serverboard DetailsFigure 5-3. X10DRT-P/PT/PIBF Serverboard Layout(not drawn to scale)

Strona 101

Chapter 5: Advanced Serverboard Setup5-13X10DRT-P/PT/PIBF Quick ReferenceJumper Description Default SettingJBT1 Clear CMOS See Section 5-9JPB1 BMC Ena

Strona 102

5-14SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL5-8 Connector DenitionsEthernet LAN PortsTwo Gigabit Ethernet ports (LAN1/2) are located o

Strona 103

Chapter 5: Advanced Serverboard Setup5-15VGA PortA VGA (video) port is provided on the I/O backplane. This connector is used to provide video and CRT

Strona 104 - IIO2 Conguration

5-16SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALFan HeaderPin Denitions Pin# Denition 1 Ground2 +12V 3 Tachometer4 PWR ModulationF

Strona 105

Chapter 5: Advanced Serverboard Setup5-175-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used to

Strona 106 - QPI Status

5-18SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALWatch Dog Enable/DisableWatch Dog (JWD1) is a system monitor that can reboot the system when

Strona 107 - Memory Conguration

Chapter 5: Advanced Serverboard Setup5-195-10 Onboard IndicatorsIPMI Dedicated LAN Port LEDsIn addition to the Gigabit Ethernet ports, an IPMI Dedica

Strona 108 - DIMM Information

vii2-5 Installing the System into a Rack ... 2-4Identifying the Sections of the Rack

Strona 109

5-20SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALInniBand Link LED (Green)StatusColor Status DenitionGreen Solid InniBand Con

Strona 110 - •USB Devices

Chapter 5: Advanced Serverboard Setup5-215-11 PCI-Express and SATA ConnectionsS-SATA 0-2/CPU2_PCI-Express 3.0 x16 Slot (SXB1)A CPU2_PCI-Express 3.0 x

Strona 111

5-22SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALFigure 5-6. Driver/Tool Installation Display Screen5-12 Installing SoftwareThe Supermicro f

Strona 112 - •Software Preserve Support

Chapter 5: Advanced Serverboard Setup5-23SuperDoctor® 5The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interfa

Strona 113

5-24SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL5-13 Onboard BatteryPlease handle used batteries carefully. Do not damage the battery in an

Strona 114

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainten

Strona 115

6-2SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL6-2 Control PanelThe control panel is located on the front of the chassis. The LEDs inform y

Strona 116

Chapter 6: Advanced Chassis Setup6-36-3 Chassis CoverBefore operating the SC217HQ+ chassis for the rst time, it is important to remove the protecti

Strona 117 - •PCI Device Common Settings

6-4SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL6-4 Air ShroudsAir shrouds concentrate airow to maximize fan efciency. The SC217HQ+ chassi

Strona 118

Chapter 6: Advanced Chassis Setup6-56-5 Checking the AirowChecking Airow1. Make sure there are no objects obstructing the airow in and out of the

Strona 119 - Super IO Conguration

viiiInstalling a Passive CPU Heatsink ... 5-7Removing the Heatsink ...

Strona 120

6-6SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALChanging a System Fan1. If necessary, open the chassis while the power is running to determi

Strona 121

Chapter 6: Advanced Chassis Setup6-7Figure 6-5. Replacing a System Fan in the Fan Housing

Strona 122

6-8SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL6-7 Removing and Installing the BackplaneThe SC217HQ+ chassis backplane is located behind th

Strona 123

Chapter 6: Advanced Chassis Setup6-96. Loosen the three screws in the spring bar, located on the oor of the chassis, indicated by the arrows below (

Strona 124

6-10SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALFigure 6-9. Installing the BackplaneInstalling the BackplaneInstalling the Backplane into th

Strona 125 - ACPI Settings

Chapter 6: Advanced Chassis Setup6-116-8 Installing the ServerboardI/O ShieldThe I/O shield holds the serverboard ports in place. The I/O shield does

Strona 126 - 7-4 Event Logs

6-12SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL9. Connect the cables between the serverboard, backplane, chassis, front panel, and power s

Strona 127 - View SMBIOS Event Log

Chapter 6: Advanced Chassis Setup6-13Figure 6-11. Installing the Serverboard in the Serverboard Node Drawer

Strona 128 - 7-5 IPMI

6-14SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALFigure 6-12. Adapter Card Installation6-9 Adapter Card ReplacementEach serverboard drawer c

Strona 129 - •IPMI Network Link Status

Chapter 6: Advanced Chassis Setup6-15Expansion Card/PCI Slot SetupThe SC217HQ+ chassis supports one low-prole expansion PCI slot for each node, for a

Strona 130 - 7-6 Security Settings

Chapter 7 BIOS 7-1 Introduction ... 7-1Starting B

Strona 131 - 7-7 Boot Settings

6-16SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALInstalling Expansion Cards (Figure 6-14)1. Disconnect the chassis from any power source, la

Strona 132

Chapter 6: Advanced Chassis Setup6-176-10 Drive Bay Installation/RemovalAccessing the Drive BaysSATA Drives: You do not need to access the inside of

Strona 133 - 7-8 Save & Exit

6-18SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALRemoving Hard Drive Trays from the Chassis (Figure 6-16)1. Press the release button on the

Strona 134

Chapter 6: Advanced Chassis Setup6-19Figure 6-17. Chassis Drive TrayInstalling a Drive into the Hard Drive TrayThe drives are mounted in drive carrier

Strona 135 - BIOS Error Beep Codes

6-20SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL6-11 Power SupplyThe SC217HQ+ chassis includes two redundant, hot-plug 2000 Watt power supp

Strona 136

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS setup utility for the X10DRT-P/PT/PIBF. The ROM BIOS is store

Strona 137 - System Specications

7-2SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is

Strona 138

Chapter 7: BIOS7-3The following Main menu items will be displayed:System Date/System Time Use this option to change the system date and time. Highligh

Strona 139

7-4SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL7-3 Advanced Setup CongurationsUse the arrow keys to select Advanced setup and press <E

Strona 140

Chapter 7: BIOS7-5Wait For 'F1' If ErrorSelect Enabled to force the system to wait until the 'F1' key is pressed if an error occur