® SUPERUSER'S MANUALRevision 1.0SUPERSERVER®2028TP-HC1R2028TP-HC1TR2028TP-HC1FR
xNotesSUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL
7-6SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALCPU CongurationThis submenu displays the following CPU information as detected by the BIOS.
Chapter 7: BIOS7-7Hardware Prefetcher (Available when supported by the CPU)If set to Enable, the hardware prefetcher will prefetch streams of data and
7-8SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALX2 APIC (Advanced Programmable Interrupt Controller)Based on Intel's Hyper-Threading arc
Chapter 7: BIOS7-9P-state CoordinationThis feature is used to change the P-state (Power-Performance State) coordi-nation type. P-state is also known a
7-10SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALChipset CongurationWarning! Please set the correct settings for the items below. A wro
Chapter 7: BIOS7-11IOU0 (II0 PCIe Port 2)This item congures the PCI-E port Bifuraction setting for a PCI-E port specied by the user. The options are
7-12SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL Intel VT for Directed I/O (VT-d)Intel VT for Direct I/O (VT-d)Intel® VT for Directed I/O (
Chapter 7: BIOS7-13Link Speed ModeUse this item to select the data transfer speed for QPI Link connections. The options are Fast and Slow.Link Frequen
7-14SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALData ScramblingSelect Enabled to enable data scrambling to enhance system performance and d
Chapter 7: BIOS7-15the same set of operations in parallel to boost performance. The options are Disable, Mirror, and Lockstep Mode. Lockstep x4 DIMMs
Chapter 1 Introduction1-1 OverviewThe SuperServer 2028TP-HC1R/HC1TR/HC1FR is a high-end server comprised of two main subsystems: the SC217HQ+-R2K02B
7-16SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALSouth BridgeThe following South Bridge information will display:USB Conguration•USB Modu
Chapter 7: BIOS7-17EHCI2Select Enabled to enable EHCI (Enhanced Host Controller Interface) support on USB 2.0 connector #2 (-at least one USB 2.0 conn
7-18SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALSATA CongurationWhen this submenu is selected, AMI BIOS automatically detects the presence
Chapter 7: BIOS7-19Port 0 ~ Port 5 SATA Device TypeUse this item to specify if the SATA port specied by the user should be con-nected to a Sol
7-20SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALPort 0 ~ Port 5 Hot PlugSelect Enabled to enable hot-plugging support for a port specied by
Chapter 7: BIOS7-21•Software Preserve Support sSATA Port 0~ Port 3Select Enabled to enable an sSATA port specied by the user. The options are Disabl
7-22SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALsSATA RAID Option ROM/UEFI DriverSelect EFI to load the EFI driver for system boot. Select L
Chapter 7: BIOS7-23•ME Firmware Status #2•Current State•Error CodePCIe/PCI/PnP CongurationThe following PCI information will be displayed:•PCI B
7-24SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALMaximum Read RequestSelect Auto for the system BIOS to automatically set the maximum size fo
Chapter 7: BIOS7-25Network StackSelect Enabled to enable PXE (Preboot Execution Environment) or UEFI (Uni-ed Extensible Firmware Interface) for
1-2SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL1-2 Serverboard FeaturesAt the heart of the SuperServer 2028TP-HC1R/HC1TR/HC1FR lies the X10
7-26SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL*If the item above set to Enabled, the following items will become available fo
Chapter 7: BIOS7-27VT-UTF8 Combo Key SupportSelect Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Enabled
7-28SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALSOL/COM2 Console Redirection SettingsUse this feature to specify how the host computer will
Chapter 7: BIOS7-29VT-UTF8 Combo Key SupportSelect Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Enabled
7-30SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALEMS Console Redirection Settings (Available when EMS Console Redirection is enabled)Use thi
Chapter 7: BIOS7-31port to enhance data integrity and network security. Please reboot the system for a change on this setting to take effect. The opti
7-32SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL7-4 Event LogsUse this feature to congure Event Log settings.Change SMBIOS Event Log Set
Chapter 7: BIOS7-33Erasing SettingsErase Event LogSelect Yes to erase all error events in the SMBIOS (System Management BIOS) log before an event logg
7-34SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL7-5 IPMIUse this feature to congure Intelligent Platform Management Interface (I
Chapter 7: BIOS7-35When SEL is FullThis feature allows the user to determine what the AMI BIOS should do when the system event log is full. Select Era
1-3Chapter 1: IntroductionPCI Expansion SlotsThe SuperServer 2028TP-HC1R/HC1TR/HC1FR has for each node one (1) PCI Express 3.0 x16 slot (Slot 1) avail
7-36SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL7-6 Security SettingsThis menu allows the user to congure the following security
Chapter 7: BIOS7-377-7 Boot SettingsUse this feature to congure Boot Settings:Boot CongurationSetup Prompt TimeoutUse this item to indicate how man
7-38SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL•Dual Boot Order #7•Dual Boot Order #8•Dual Boot Order #9•Dual Boot Order #10•Dual Boot
Chapter 7: BIOS7-397-8 Save & ExitSelect the Save & Exit tab from the BIOS setup screen to congure the settings below.Discard Chang
7-40SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALRestore DefaultsSelect this item and press <Enter> to load the manufacture default set
A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time th
A-2SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALNotes
B-1Appendix B: System SpecicationsAppendix B System SpecicationsNote: Unless noted specications apply to a complete system (all serverboards).Pro
B-2SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALChassisSC217HQ+-R2K02B (2U rackmount) Dimensions: (WxHxD) 17.25 x 3.47 x 28.5 in. (438 x 88 x
B-3Appendix B: System SpecicationsNotes
1-4SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL1-3 Server Chassis FeaturesThe following is a general outline of the main features of the SC
B-4SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL(continued from front)The products sold by Supermicro are not intended for and will not be us
1-5Chapter 1: IntroductionFigure 1-1. Intel PCH C612 Chipset: System Block DiagramNote: This is a general block diagram and may not exactly repre-sen
1-6SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL1-5 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jos
1-7Chapter 1: Introduction1-6 2U Twin2: System NotesAs a 2U Twin2 conguration, the SuperServer 2028TP-HC1R/HC1TR/HC1FR is a unique server system. Wi
1-8SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALNotes
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 2028
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu
2-2SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALChoosing a Setup Location•Leave enough clearance in front of the rack to enable you to open
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
2-4SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL2-5 Installing the System into a RackThis section provides information on installing the 202
Chapter 2: Server Installation2-5Figure 2-2. Extending and Releasing the Inner RailLocking TabsEach inner rail has a locking tab. This tab locks the c
2-6SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALFigure 2-3. Installing the Inner Rails Installing The Inner Rails on the ChassisTo install th
Chapter 2: Server Installation2-7Figure 2-5. Extending and Releasing the Outer Rails1112131421D01L-min=676.00(26.61")(outer rail)Installing the O
2-8SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALFigure 2-6. Installing into a RackBall-Bearing ShuttleStandard Chassis InstallationInstalling
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel and on the drive carriers to keep yo
SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL3-23-2 Control Panel ButtonAlertThis LED is illuminated when an alert condition occurs.•A soli
Chapter 3: System Interface3-3•A ashing red light which ashes in four second interfals indicates a power failure. When notied of an al
iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta
SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL3-4Notes
4-1Chapter 4: Warning Statements for AC SystemsChapter 4 Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe
4-2SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie benden sich in
4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기
4-4SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALInstallation Instructions Warning!Read the installation instructions before connecting the sy
4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over
4-6SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALPower Disconnection Warning Warning!The system must be disconnected from all sources of power
4-7Chapter 4: Warning Statements for AC SystemsWarnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt sein, das von
4-8SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALEquipment Installation Warning!Only trained and qualied personnel should be allowed to insta
4-9Chapter 4: Warning Statements for AC SystemsRestricted Area Warning!This unit is intended for installation in restricted access areas. A restricted
SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALivChapter 6: Advanced Chassis SetupRefer to Chapter 6 for detailed information on the SC217HQ+-R
4-10SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALBattery Handling Warning!There is the danger of explosion if the battery is replaced incorre
4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur
4-12SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALRedundant Power Supplies Warning!This unit might have more than one power supply connection.
4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltage Warning!Hazardous voltage or energy is present on the backplane when the system is o
4-14SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALComply with Local and National Electrical Codes Warning!Installation of the equipment must c
4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national
4-16SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALWarnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Land
4-17Chapter 4: Warning Statements for AC Systems!הרהזא יקלח תא םיריסמ רשאכ שי .םידבוע ןיידע םיררוואמהו ןכתי ,זראמהמ ררוואמה קיחרהללררוואמה ךותב םיחתפ
4-18SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALPower Cable and AC Adapter Warning!When installing the product, use the provided or designa
4-19Chapter 4: Warning Statements for AC Systems¡Advertencia! Al instalar el producto, utilice los cables de conexión previstos o designados, los cabl
vSUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALNotes
4-20SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALWaarschuwing Bij het installeren van het product, gebruik de meegeleverde of aangewezen kabe
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X10DRT-P/PT/PIBF s
5-2SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL5-2 Connecting CablesNow that the processors are installed, the next step is to connect the
Chapter 5: Advanced Serverboard Setup5-35-3 Rear I/O PortsSee Figure 5-1 below for the and locations of the various rear I/O ports and the UID switch
5-4SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL5-4 Processor and Heatsink InstallationNotes: •Always remove the power cord before adding,
Chapter 5: Advanced Serverboard Setup5-53. With the second lever fully retracted, gently push down on the "Open 1st" lever to loosen the lo
5-6SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL8. Make sure the locking mechanism on the "Close 1st" lever catches the lip of the
Chapter 5: Advanced Serverboard Setup5-7Installing a Passive CPU Heatsink1. Do not apply any thermal grease to the heatsink or the CPU die -- the req
5-8SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALRemoving the HeatsinkCaution: We DO NOT recommend that the CPU or the heatsink be removed. Ho
Chapter 5: Advanced Serverboard Setup5-95-5 Installing MemoryInstalling Memory1. Insert each memory module vertically into its slot, paying attentio
viTable of ContentsChapter 1 Introduction1-1 Overview ...
5-10SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALProcessor & Memory Module Population CongurationFor the memory to work properly, follow
Chapter 5: Advanced Serverboard Setup5-115-6 Adding PCI Expansion CardsThe 2028TP-HC1R/HC1TR/HC1FR includes one preinstalled riser card per node, des
5-12SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL5-7 Serverboard DetailsFigure 5-3. X10DRT-P/PT/PIBF Serverboard Layout(not drawn to scale)
Chapter 5: Advanced Serverboard Setup5-13X10DRT-P/PT/PIBF Quick ReferenceJumper Description Default SettingJBT1 Clear CMOS See Section 5-9JPB1 BMC Ena
5-14SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL5-8 Connector DenitionsEthernet LAN PortsTwo Gigabit Ethernet ports (LAN1/2) are located o
Chapter 5: Advanced Serverboard Setup5-15VGA PortA VGA (video) port is provided on the I/O backplane. This connector is used to provide video and CRT
5-16SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALFan HeaderPin Denitions Pin# Denition 1 Ground2 +12V 3 Tachometer4 PWR ModulationF
Chapter 5: Advanced Serverboard Setup5-175-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used to
5-18SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALWatch Dog Enable/DisableWatch Dog (JWD1) is a system monitor that can reboot the system when
Chapter 5: Advanced Serverboard Setup5-195-10 Onboard IndicatorsIPMI Dedicated LAN Port LEDsIn addition to the Gigabit Ethernet ports, an IPMI Dedica
vii2-5 Installing the System into a Rack ... 2-4Identifying the Sections of the Rack
5-20SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALInniBand Link LED (Green)StatusColor Status DenitionGreen Solid InniBand Con
Chapter 5: Advanced Serverboard Setup5-215-11 PCI-Express and SATA ConnectionsS-SATA 0-2/CPU2_PCI-Express 3.0 x16 Slot (SXB1)A CPU2_PCI-Express 3.0 x
5-22SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALFigure 5-6. Driver/Tool Installation Display Screen5-12 Installing SoftwareThe Supermicro f
Chapter 5: Advanced Serverboard Setup5-23SuperDoctor® 5The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interfa
5-24SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL5-13 Onboard BatteryPlease handle used batteries carefully. Do not damage the battery in an
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainten
6-2SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL6-2 Control PanelThe control panel is located on the front of the chassis. The LEDs inform y
Chapter 6: Advanced Chassis Setup6-36-3 Chassis CoverBefore operating the SC217HQ+ chassis for the rst time, it is important to remove the protecti
6-4SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL6-4 Air ShroudsAir shrouds concentrate airow to maximize fan efciency. The SC217HQ+ chassi
Chapter 6: Advanced Chassis Setup6-56-5 Checking the AirowChecking Airow1. Make sure there are no objects obstructing the airow in and out of the
viiiInstalling a Passive CPU Heatsink ... 5-7Removing the Heatsink ...
6-6SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALChanging a System Fan1. If necessary, open the chassis while the power is running to determi
Chapter 6: Advanced Chassis Setup6-7Figure 6-5. Replacing a System Fan in the Fan Housing
6-8SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL6-7 Removing and Installing the BackplaneThe SC217HQ+ chassis backplane is located behind th
Chapter 6: Advanced Chassis Setup6-96. Loosen the three screws in the spring bar, located on the oor of the chassis, indicated by the arrows below (
6-10SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALFigure 6-9. Installing the BackplaneInstalling the BackplaneInstalling the Backplane into th
Chapter 6: Advanced Chassis Setup6-116-8 Installing the ServerboardI/O ShieldThe I/O shield holds the serverboard ports in place. The I/O shield does
6-12SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL9. Connect the cables between the serverboard, backplane, chassis, front panel, and power s
Chapter 6: Advanced Chassis Setup6-13Figure 6-11. Installing the Serverboard in the Serverboard Node Drawer
6-14SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALFigure 6-12. Adapter Card Installation6-9 Adapter Card ReplacementEach serverboard drawer c
Chapter 6: Advanced Chassis Setup6-15Expansion Card/PCI Slot SetupThe SC217HQ+ chassis supports one low-prole expansion PCI slot for each node, for a
Chapter 7 BIOS 7-1 Introduction ... 7-1Starting B
6-16SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALInstalling Expansion Cards (Figure 6-14)1. Disconnect the chassis from any power source, la
Chapter 6: Advanced Chassis Setup6-176-10 Drive Bay Installation/RemovalAccessing the Drive BaysSATA Drives: You do not need to access the inside of
6-18SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALRemoving Hard Drive Trays from the Chassis (Figure 6-16)1. Press the release button on the
Chapter 6: Advanced Chassis Setup6-19Figure 6-17. Chassis Drive TrayInstalling a Drive into the Hard Drive TrayThe drives are mounted in drive carrier
6-20SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL6-11 Power SupplyThe SC217HQ+ chassis includes two redundant, hot-plug 2000 Watt power supp
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS setup utility for the X10DRT-P/PT/PIBF. The ROM BIOS is store
7-2SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUALHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is
Chapter 7: BIOS7-3The following Main menu items will be displayed:System Date/System Time Use this option to change the system date and time. Highligh
7-4SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL7-3 Advanced Setup CongurationsUse the arrow keys to select Advanced setup and press <E
Chapter 7: BIOS7-5Wait For 'F1' If ErrorSelect Enabled to force the system to wait until the 'F1' key is pressed if an error occur
Komentarze do niniejszej Instrukcji