Supermicro A+ Server 2041M-T2R+B Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Kluczowe komponenty serwerowe Supermicro A+ Server 2041M-T2R+B. Supermicro 2041M-32R+B Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 106
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - SUPER

AS2041M-32R+AS2041M-T2R+USER’S MANUAL1.0 SUPER®

Strona 2 - Release Date: August 8, 2007

xAS2041M-32R+/2041M-T2R+ User's Manual7-4 Boot Menu ...

Strona 3 - Manual Organization

B-6AS2041M-32R+/2041M-T2R+ User's ManualCheckpoint Code Description 86h The password was checked. Performing any required programming bef

Strona 4

B-7Appendix B: BIOS POST Checkpoint CodesCheckpoint Code Description A9h Returned from adaptor ROM at E000h control. Performing any initializa

Strona 5

B-8AS2041M-32R+/2041M-T2R+ User's ManualNotes

Strona 6 - Table of Contents

C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessorsSingle, dual or quad AMD Opteron 8000 series (Socket F) type processors

Strona 7 - Chapter 4 System Safety

C-2AS2041M-32R+/2041M-T2R+ User's ManualExpansion SlotsTwo PCI-Express x16 slots, one PCI-Express x8 slot, one PCI-Express x4 slot (x8 slot using

Strona 8

C-3Appendix C: System Specifi cationsOperating Environment Operating Temperature: 10º to 35º C (50º to 95º F) Non-operating Temperature: -40º

Strona 9 - Chapter 7 BIOS

C-4AS2041M-32R+/2041M-T2R+ User's ManualNotes

Strona 10

Chapter 1 Introduction1-1 OverviewThe AS2041M-32R+/2041M-T2R+ is a 2U server comprised of two main subsys-tems: the SC828TQ-R1200 server chassis and t

Strona 11 - Introduction

1-2AS2041M-32R+/2041M-T2R+ User's Manual1-2 Serverboard FeaturesAt the heart of the AS2041M-32R+/2041M-T2R+ lies the H8QM3-2/H8QMi-2, a quad proc

Strona 12 - 1-2 Serverboard Features

1-3Chapter 1: IntroductionOnboard Controllers/PortsOne fl oppy drive controller and an ATA/133 controller are provided to support fl oppy and IDE hard d

Strona 13 - 1-3 Server Chassis Features

1-4AS2041M-32R+/2041M-T2R+ User's ManualControl PanelThe control panel provides you with system monitoring and control functions. LEDs indicate

Strona 14 - DIM M s 1A ~ 4B

1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408)

Strona 15 - 1-4 Contacting Supermicro

1-6AS2041M-32R+/2041M-T2R+ User's ManualNotes

Strona 16

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your 2041M-32R+/2041M-

Strona 17 - Server Installation

2-2AS2041M-32R+/2041M-T2R+ User's Manual! !Warnings and Precautions!Choosing a Setup Location- Leave enough clearance in front of the rack to ena

Strona 18 - Warnings and Precautions!

Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am

Strona 19 - Rack Mounting Considerations

Unless you request and receive written permission from SUPER MICRO COMPUTER, you may not copy any part of this document.Information in this document i

Strona 20 - Installing the Chassis Rails

2-4AS2041M-32R+/2041M-T2R+ User's Manual2-4 Installing the System into a RackThis section provides information on installing the AS2041M-32R+/20

Strona 21 - Installing the Rack Rails:

Chapter 2: Server Installation2-5Figure 2-1. Installing Chassis RailsInstalling the Rack Rails:Determine where you want to place the AS2041M-32R+/2041

Strona 22

2-6AS2041M-32R+/2041M-T2R+ User's ManualFigure 2-2. Installing the Server into a RackInstalling the Server into the RackYou should now have rail

Strona 23

Chapter 2: Server Installation2-7Figure 2-3. Installing the Server into a Telco RackInstalling the Server into a Telco RackTo install the AS2041M-32

Strona 24

2-8AS2041M-32R+/2041M-T2R+ User's Manual2-5 Checking the Serverboard SetupAfter you install the AS2041M-32R+/2041M-T2R+ in the rack, you will ne

Strona 25

Chapter 2: Server Installation2-9Figure 2-4. Accessing the Inside of the System

Strona 26

2-10AS2041M-32R+/2041M-T2R+ User's Manual2-6 Checking the Drive Bay SetupNext, you should check to make sure the peripheral drives and the SAS/S

Strona 27 - System Interface

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the SAS and SATA

Strona 28 - 3-3 Control Panel LEDs

3-2AS2041M-32R+/2041M-T2R+ User's Manual3-3 Control Panel LEDsThe control panel located on the front of th SC815TQ-560C chassis has fi ve LEDs. T

Strona 29 - 3-4 Drive Carrier LEDs

Chapter 3: System Interface3-3PowerIndicates power is being supplied to the system's power supply units. This LED should normally be illuminated

Strona 30

iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the inst

Strona 31 - System Safety

3-4AS2041M-32R+/2041M-T2R+ User's ManualNotes

Strona 32

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety PrecautionsBasic electrical safety precautions should be followed to protect

Strona 33 - 4-3 ESD Precautions

AS2041M-32R+/2041M-T2R+ User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety:  Keep the area around the 2

Strona 34 - BATTERY HOLDER BATTERY HOLDER

Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic discharge (ESD) is generated by two objects with different electrical charges coming into

Strona 35 - Advanced Serverboard Setup

AS2041M-32R+/2041M-T2R+ User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the 2041M-3

Strona 36 - Triangles

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install processors and heatsink

Strona 37

5-2AS2041M-32R+/2041M-T2R+ User's Manual5-2 Processor and Heatsink InstallationInstalling the Processors(Install to the CPU#1 socket fi rst) 1. B

Strona 38 - Installing the Heatsink

Chapter 5: Advanced Serverboard Setup5-33. Align pin 1 of the CPU with pin 1 of the socket. Once aligned, care-fully place the CPU into the socket.

Strona 39 - 5-3 Connecting Cables

5-4AS2041M-32R+/2041M-T2R+ User's ManualInstalling the HeatsinkThe use of active type heatsinks are recommended. Connect the heatsink fans to th

Strona 40 - 20 19

Chapter 5: Advanced Serverboard Setup5-55-3 Connecting CablesNow that the processors are installed, the next step is to connect the cables to the ser

Strona 41 - 5-5 Installing Memory

AS2041M-32R+/2041M-T2R+ User's ManualivChapter 4: System SafetyYou should thoroughly familiarize yourself with this chapter for a general overvi

Strona 42 - Note: Notch

5-6AS2041M-32R+/2041M-T2R+ User's ManualFigure 5-2. Front Control Panel Header Pins (JF1)Connecting the Control PanelJF1 contains header pins for

Strona 43 - 5-6 Adding PCI Cards

Chapter 5: Advanced Serverboard Setup5-75-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 below

Strona 44 - 5-7 Serverboard Details

5-8AS2041M-32R+/2041M-T2R+ User's ManualFigure 5-4. Installing DIMM into SlotSupportThe H8QM3-2 supports single or dual-channel, registered ECC D

Strona 45

Chapter 5: Advanced Serverboard Setup5-95-6 Adding PCI CardsPCI Expansion SlotsThe SC828TQ-R1200 chassis can accommodate up to seven low-profi le PCI a

Strona 46 - 5-8 Connecting Cables

5-10AS2041M-32R+/2041M-T2R+ User's ManualFigure 5-5. Serverboard Layout(not drawn to scale)5-7 Serverboard DetailsNotes:Jumpers not indicated are

Strona 47

Chapter 5: Advanced Serverboard Setup5-11H8QM3-2/H8QMi-2 Quick ReferenceJumpers Description Default Setting JBT1 CMOS Clear (See Sectio

Strona 48 - USB Headers

5-12AS2041M-32R+/2041M-T2R+ User's Manual5-8 Connecting CablesATX Power ConnectorThe primary ATX power supply con-nector (J1B1) meets the SSI (Su

Strona 49 - Power LED/Speaker

Chapter 5: Advanced Serverboard Setup5-13Overheat/Fan Fail LEDConnect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad-vanced warning

Strona 50

5-14AS2041M-32R+/2041M-T2R+ User's ManualReset ButtonThe Reset Button connection is lo-cated on pins 3 and 4 of JF1. Attach it to the hardware r

Strona 51 - Compact Flash Power

Chapter 5: Advanced Serverboard Setup5-15Fan HeadersThe serverboard has nine fan head-ers, which are designated FAN1 through FAN9. Fans speed may be

Strona 53

5-16AS2041M-32R+/2041M-T2R+ User's ManualATX PS/2 Keyboard and PS/2 Mouse PortsThe ATX PS/2 keyboard and the PS/2 mouse ports are located at J3.

Strona 54 - PCI-X Slot Speed

Chapter 5: Advanced Serverboard Setup5-17Wake-On-RingThe Wake-On-Ring header is desig-nated JWOR. This function allows your computer to receive and &

Strona 55 - 5-10 Onboard Indicators

5-18AS2041M-32R+/2041M-T2R+ User's ManualCMOS ClearJBT1 is used to clear CMOS and will also clear any passwords. Instead of pins, this jumper co

Strona 56 - Floppy Connector

Chapter 5: Advanced Serverboard Setup5-19VGA Enable/DisableJPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and 2

Strona 57 - SATA Ports

5-20AS2041M-32R+/2041M-T2R+ User's ManualCompact Flash Master/Slave The JCF1 jumper allows you to assign either master or slave status to a com-p

Strona 58 - SIMLC (IPMI Slot)

Chapter 5: Advanced Serverboard Setup5-215-10 Onboard IndicatorsJLAN LED (Connection Speed Indicator)LED Color Defi nition Off 10 MHzGreen 100

Strona 59 - 5-12 Enabling SATA RAID

5-22AS2041M-32R+/2041M-T2R+ User's Manual5-11 Floppy, IDE, SATA and SAS Drive ConnectionsUse the following information to connect the fl oppy and

Strona 60 - Installing the OS and Drivers

Chapter 5: Advanced Serverboard Setup5-23IDE ConnectorThere are no jumpers to con-fi gure the onboard IDE connec-tor. See the table on the right for p

Strona 61

5-24AS2041M-32R+/2041M-T2R+ User's ManualSAS PortsThere are two SAS ports, one located on the backplane and the other on the serverboard near the

Strona 62

Chapter 5: Advanced Serverboard Setup5-255-12 Enabling SATA RAIDNote: For SAS RAID, please refer to LSI manual on the driver CD.Serial ATA (SATA)Seri

Strona 63 - Advanced Chassis Setup

viAS2041M-32R+/2041M-T2R+ User's ManualTable of ContentsPrefaceAbout This Manual ...

Strona 64 - 6-2 Control Panel

5-26AS2041M-32R+/2041M-T2R+ User's Manual2. Use the arrow keys to move to the "Advanced" menu, then scroll down to "nVidia RAID Fu

Strona 65 - Replacing System Cooling Fans

Chapter 5: Advanced Serverboard Setup5-27Figure 5-6. SATA RAID Utility: Main ScreenFigure 5-7. SATA RAID Utility: Array List

Strona 66 - Installing the Air Shroud

5-28AS2041M-32R+/2041M-T2R+ User's Manual5-13 Installing Software DriversAfter all the hardware and operating system have been installed, you nee

Strona 67

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform main-tena

Strona 68 - Accessing the Drive Bays

6-2AS2041M-32R+/2041M-T2R+ User's ManualFigure 6-1. Chassis: Front and Rear Views6-2 Control PanelThe control panel (located on the front of the

Strona 69

Chapter 6: Advanced Chassis Setup6-36-3 System Fans and Air ShroudSix 8-cm heavy duty fans provide the cooling for the 2041M-32R+/2041M-T2R+. The fa

Strona 70 - SAS/SATA Backplane

6-4AS2041M-32R+/2041M-T2R+ User's ManualFigure 6-2. System Cooling FansInstalling the Air ShroudAir shrouds concentrate airfl ow to maximize fan

Strona 71

Chapter 6: Advanced Chassis Setup6-5Figure 6-3. Installing the Air Shroud

Strona 72 - 6-5 Power Supply

6-6AS2041M-32R+/2041M-T2R+ User's Manual6-4 Drive Bay Installation/RemovalAccessing the Drive BaysSATA Drives: Because of their hotswap capabilit

Strona 73

Chapter 6: Advanced Chassis Setup6-7Figure 6-4. Mounting a SAS/SATA Drive in a Carrier!Important: Regardless of how many SAS/SATA hard drives are inst

Strona 74

viiTable of Contents2-6 Checking the Drive Bay Setup ... 2-10Chapter 3 System Inte

Strona 75 - Chapter 7

6-8AS2041M-32R+/2041M-T2R+ User's ManualFigure 6-5. Removing a SAS/SATA Drive from the ServerSAS/SATA BackplaneThe SAS/SATA drives plug into a ba

Strona 76 - 7-3 Advanced Settings Menu

Chapter 6: Advanced Chassis Setup6-9DVD-ROM and Floppy Drive InstallationThe top cover of the chassis must be opened to gain full access to the DVD-RO

Strona 77 - ACPI Version Features

6-10AS2041M-32R+/2041M-T2R+ User's Manual6-5 Power SupplyThe AS2041M-32R+/2041M-T2R+ has a 1200 watt redundant power supply con-fi guration consi

Strona 78 - CPU Confi guration

Chapter 6: Advanced Chassis Setup6-11Figure 6-6. Removing/Replacing the Power Supply

Strona 79

6-12AS2041M-32R+/2041M-T2R+ User's ManualNotes

Strona 80

Chapter 7: BIOS7-1Chapter 7 BIOS7-1 IntroductionThis chapter describes the AMIBIOS™ Setup utility for the H8QM3-2/H8QMi-2. The AMI ROM BIOS is stored

Strona 81

7-2AS2041M-32R+/2041M-T2R+ User's Manual7-2 Main MenuWhen you fi rst enter AMI BIOS Setup Utility, you will see the Main Menu screen. You can alwa

Strona 82

Chapter 7: BIOS7-3Boot up Num-LockSet this value to allow the Number Lock setting to be modifi ed during boot up. The options are On and Off.PS/2 Mouse

Strona 83 - PCI/PnP Confi guration

7-4AS2041M-32R+/2041M-T2R+ User's ManualMCP55 ACPI HPET TableUse this setting to either Enable or Disable the MCP55 ACPI HPET table.Power Confi gu

Strona 84 - Super IO Confi guration

Chapter 7: BIOS7-5Thermal ThrottlingThis setting is used to Enable or Disable Thermal Throttling.Microcode UpdateThis setting is used to Enable or Dis

Strona 85 - NorthBridge Confi guration

viiiAS2041M-32R+/2041M-T2R+ User's Manual5-8 Connecting Cables ...

Strona 86

7-6AS2041M-32R+/2041M-T2R+ User's ManualPrimary IDE Master/SlaveHighlight one of the items above and press <Enter> to access the submenu fo

Strona 87

Chapter 7: BIOS7-7UDMA4 and UDMA5. (SWDMA=Single Word DMA, MWDMA=Multi Word DMA, UDMA=UltraDMA.)S.M.A.R.T.Self-Monitoring Analysis and Reporting Techn

Strona 88 -  PCI Express Confi guration

7-8AS2041M-32R+/2041M-T2R+ User's ManualBIOS to auto detect the PIO mode. Use this value if the IDE disk drive support cannot be determined. Sele

Strona 89 -  System Fan Monitor

Chapter 7: BIOS7-9 PCI/PnP Confi guration Clear NVRAMSelect Yes to clear NVRAM during boot-up. The options are Yes and No.Plug & Play OSSelect Y

Strona 90 - 7-4 Boot Menu

7-10AS2041M-32R+/2041M-T2R+ User's ManualIRQ3/IRQ4/IRQ5/IRQ7/IRQ9/IRQ10/IRQ11/IRQ14/IRQ15This feature specifi es the availability of an IRQ to be

Strona 91 - 7-5 Security Menu

Chapter 7: BIOS7-11 Chipset Confi guration NorthBridge Confi guration Memory Confi guration Memclock ModeThis setting determines how the memory clo

Strona 92 - 7-6 Exit Menu

7-12AS2041M-32R+/2041M-T2R+ User's Manual ECC Confi guration DRAM ECC EnableDRAM ECC allows hardware to report and correct memory errors automat

Strona 93 - BIOS Error Beep Codes

Chapter 7: BIOS7-13 SouthBridge/MCP55 Confi gurationCPU/LDT Spread SpectrumEnables spread spectrum for the CPU/LDT. Options are Center Spread, Down

Strona 94 - H8QM3-2/H8QMi-2 User’s Manual

7-14AS2041M-32R+/2041M-T2R+ User's Manual Event Log Confi gurationView Event LogHighlight this item and press <Enter> to view the contents

Strona 95 - BIOS POST Checkpoint Codes

Chapter 7: BIOS7-15Redirection After BIOS POST Options are Disable (no redirection after BIOS POST), Boot Loader (redirection during POST and during b

Strona 96 - B-2 Bootblock Recovery Codes

Table of ContentsixOnboard Power LED (DP2) ... 5-215-11 Floppy, IDE, SATA and

Strona 97

7-16AS2041M-32R+/2041M-T2R+ User's Manual7-4 Boot MenuThis feature allows the user to confi gure the following items: Boot Device PriorityThis f

Strona 98

Chapter 7: BIOS7-177-5 Security MenuAMI BIOS provides a Supervisor and a User password. If you use both passwords, the Supervisor password must be set

Strona 99

7-18AS2041M-32R+/2041M-T2R+ User's Manual7-6 Exit MenuSelect the Exit tab from AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen.

Strona 100

Appendix A BIOS Error Beep CodesDuring the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occu

Strona 101

A-2H8QM3-2/H8QMi-2 User’s ManualNotes

Strona 102

B-1Appendix B: BIOS POST Checkpoint CodesAppendix B BIOS POST Checkpoint CodesWhen AMIBIOS performs the Power On Self Test, it writes checkpoint codes

Strona 103 - System Specifi cations

B-2AS2041M-32R+/2041M-T2R+ User's ManualCheckpoint Code Description E0h The onboard fl oppy controller if available is initialized. Next,

Strona 104

B-3Appendix B: BIOS POST Checkpoint CodesCheckpoint Code Description 03h The NMI is disabled. Next, checking for a soft reset or a power on co

Strona 105 - Regulatory Compliance

B-4AS2041M-32R+/2041M-T2R+ User's ManualCheckpoint Code Description 25h Interrupt vector initialization is done. Clearing the password if

Strona 106

B-5Appendix B: BIOS POST Checkpoint CodesCheckpoint Code Description 4Ch The memory below 1 MB has been cleared via a soft reset. Clearing the

Komentarze do niniejszej Instrukcji

Brak uwag