Podsumowanie treści

Strona 1 - SUPER

SUPERSERVER 6016T-URF SUPERSERVER 6016T-UF SUPERSERVER 6016T-NTRF SUPERSERVER 6016T-NTF SUPER®USER’S MANUAL1.0

Strona 2 - Release Date: April 24, 2009

1-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 6016T-URF/6016T-UF/60

Strona 3 - Manual Organization

C-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualExpansion Slots 6016T-URF/6016T-UF: Right side: (optional) 2x Gb

Strona 4

C-3Appendix C: System Specifi cationsOperating Environment Operating Temperature: 10º to 35º C (50º to 95º F) Non-operating Temperature: -40º

Strona 5

C-4SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualNotes

Strona 6 - Table of Contents

1-3Chapter 1: IntroductionGraphics ControllerThe X8DTU-F features an integrated Matrox G200eW graphics chip, which includes 8 MB of DDR2 memory.Other

Strona 7 - Chapter 4 System Safety

1-4SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual6016T-NTRF/6016T-NTF: A riser card (RSC-R1UU-E8PR, optional) on the right sid

Strona 8

1-5Chapter 1: IntroductionFigure 1-1. Intel IOH-36D/ICH10R Chipset: System Block DiagramNote: This is a general block diagram. Please see Chapter 5 f

Strona 9 - Introduction

1-6SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980

Strona 10 - 1-2 Serverboard Features

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 6016T-

Strona 11 - 1-3 Server Chassis Features

2-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual!!Warnings and Precautions!Choosing a Setup LocationLeave enough clearance in

Strona 12 - Cooling System

Chapter 2: Server Installation2-3Allow the hot plug SATA drives and power supply modules to cool before touch-• ing them.Always keep the rack's f

Strona 13 - Chapter 1: Introduction

2-4SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual2-4 Installing the System into a RackThis section provides information on in

Strona 14 - 1-4 Contacting Supermicro

Chapter 2: Server Installation2-5Installing the Outer RailsBegin by measuring the distance from the front rail to the rear rail of the rack. Attach a

Strona 15 - Server Installation

Manual Revision 1.0 Release Date: April 24, 2009The information in this User’s Manual has been carefully reviewed and is believed to be accurate

Strona 16 - Warnings and Precautions!

2-6SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualFigure 2-3. Installing the Server into a RackInstalling the Server into the

Strona 17 - Rack Mounting Considerations

Chapter 2: Server Installation2-7Figure 2-4. Installing the Server into a Telco RackInstalling the Server into a Telco RackTo install the 6016T-URF/6

Strona 18 - Installing the Inner Rails

2-8SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual2-5 Checking the Serverboard SetupAfter you install the 6016T-URF/6016T-UF/6

Strona 19 - Installing the Outer Rails

Chapter 2: Server Installation2-9Figure 2-5. Accessing the Inside of the System2-6 Checking the Drive Bay SetupNext, you should check to make sure t

Strona 20

2-10SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualChecking the Airfl owAirfl ow is provided by four sets of 4-cm fans (each set

Strona 21

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the SATA drive ca

Strona 22

3-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualPowerThe main power button is used to apply or remove power from the power su

Strona 23

Chapter 3: System Interface3-3NIC2Indicates network activity on LAN2 when fl ashing.21NIC1Indicates network activity on LAN1 when fl ashing.HDDOn the Su

Strona 24

3-4SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual3-4 Hard Drive Carrier LEDsEach hard drive carrier has two LEDs.Green:• W

Strona 25 - System Interface

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect

Strona 26 - 3-3 Control Panel LEDs

iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It pro-vides information for the inst

Strona 27

4-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual4-2 General Safety PrecautionsFollow these rules to ensure general safety:Ke

Strona 28 - 3-4 Hard Drive Carrier LEDs

Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic discharge (ESD) is generated by two objects with different electrical charges coming into

Strona 29 - System Safety

4-4SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual4-4 Operating PrecautionsCare must be taken to assure that the chassis cover

Strona 30

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install processors and heatsinks

Strona 31 - 4-3 ESD Precautions

5-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual5-2 Processor and Heatsink InstallationIMPORTANT! Always connect the power c

Strona 32 - 4-4 Operating Precautions

Chapter 5: Advanced Serverboard Setup5-3After removing the plastic cap, use 1. your thumb and the index fi nger to hold the CPU at the north and south

Strona 33 - Advanced Serverboard Setup

5-4SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualThermal GreaseCPUPlace the heatsink on top of the 1. CPU so that the four mou

Strona 34 - Installing LGA1366 Processors

Chapter 5: Advanced Serverboard Setup5-5Unplug the power cord from the power supply.1. Unscrew and remove the heatsink screws in the 1. sequence shown

Strona 35 - Load Plate

5-6SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual5-3 Connecting CablesNow that the processors are installed, the next step is

Strona 36 - Installing the Heatsink

Chapter 5: Advanced Serverboard Setup5-7Figure 5-1. Front Control Panel Header Pins (JF1)See the Connector Defi nitions section in this chapter for det

Strona 37 - Removing the Heatsink

SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information

Strona 38 - 5-3 Connecting Cables

5-8SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual5-5 Installing MemoryNote: Check the Supermicro web site for recommended memo

Strona 39 - 5-4 I/O Ports

Chapter 5: Advanced Serverboard Setup5-9Figure 5-3. Installing DIMM into SlotPossible System Memory Allocation & AvailabilitySystem Device Size Ph

Strona 40 - 5-5 Installing Memory

5-10SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual5-6 Adding PCI CardsPCI Expansion SlotsRiser cards are used to support add-

Strona 41

Chapter 5: Advanced Serverboard Setup5-11Figure 5-4. SUPER X8DTU-F Layout(not drawn to scale)5-7 Serverboard DetailsKB /MSIPMI LANUSB 0/1COM1VGALAN1U

Strona 42 - 5-6 Adding PCI Cards

5-12SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualX8DTU-F Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear (Se

Strona 43 - 5-7 Serverboard Details

Chapter 5: Advanced Serverboard Setup5-135-8 Connector Defi nitionsPower LED The Power LED connection is located on pins 15 and 16 of JF1. Refer to the

Strona 44 - X8DTU-F Quick Reference

5-14SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualNIC1 LEDThe NIC1 (Network Interface Control-ler) LED connection is located o

Strona 45 - 5-8 Connector Defi nitions

Chapter 5: Advanced Serverboard Setup5-15Reset Button The Reset Button connection is lo-cated on pins 3 and 4 of JF1. Attach it to the hardware reset

Strona 46

5-16SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualFan HeadersThe X8DTU-F has eight headers, designated Fan1 through Fan8. FAN1

Strona 47

Chapter 5: Advanced Serverboard Setup5-17ATX PS/2 Keyboard and PS/2 Mouse PortsThe ATX PS/2 keyboard and the PS/2 mouse ports are located beside the U

Strona 48

vPrefaceNotes

Strona 49

5-18SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualLAN1/2 (Ethernet Ports)Two Ethernet ports (designated LAN1 and LAN2) are loc

Strona 50

Chapter 5: Advanced Serverboard Setup5-195-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used to c

Strona 51 - 5-9 Jumper Settings

5-20SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualLAN Enable/Disable Change the setting of jumper JPL1 to enable or disable th

Strona 52

Chapter 5: Advanced Serverboard Setup5-21BMC/PHY ResetJumper JPRST1 allow the user to reset the Winbond WPCM450 BMC (Base-board Management Controller)

Strona 53

5-22SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual5-10 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the

Strona 54 - 5-10 Onboard Indicators

Chapter 5: Advanced Serverboard Setup5-235-11 SATA Port ConnectionsSATA PortsSee the table on the right for pin defi nitions for the onboard SATA port

Strona 55 - 5-11 SATA Port Connections

5-24SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual5-12 Installing SoftwareAfter the hardware has been installed, you should fi

Strona 56 - 5-12 Installing Software

Chapter 5: Advanced Serverboard Setup5-25Supero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports remote management

Strona 57 - Supero Doctor III

5-26SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualNote: SD III Software Revision 1.0 can be downloaded from our Web Site at: f

Strona 58

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na

Strona 59 - Advanced Chassis Setup

viSUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...

Strona 60 - 6-2 Control Panel

6-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualFigure 6-1. Chassis: Front and Rear ViewsSystem Reset6-2 Control PanelThe co

Strona 61 - 6-3 System Fans

Chapter 6: Advanced Chassis Setup6-36-3 System FansFour 4-cm heavy duty counter-rotating fans provide the cooling for the SuperServer 6016T-URF/6016T-

Strona 62 - Removing the Front Bezel

6-4SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualFigure 6-2. System Cooling Fans6-4 Drive Bay Installation/RemovalRemoving t

Strona 63 - Accessing the Drive Bays

Chapter 6: Advanced Chassis Setup6-5Accessing the Drive BaysHard Drives: Because of their hotswap capability, you do not need to access the inside of

Strona 64 - Hard Drive Installation

6-6SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualHard Drive InstallationThe hard drives are mounted in drive carriers to simpl

Strona 65

Chapter 6: Advanced Chassis Setup6-7Installing/Removing a Hard DriveTo remove a carrier, push the release button located beside the drive LEDs.1. Swin

Strona 66 - DVD-ROM Drive Installation

6-8SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualDVD-ROM Drive InstallationThe top cover of the chassis must be opened to gain

Strona 67 - 6-5 Power Supply

Chapter 6: Advanced Chassis Setup6-96-5 Power Supply6016T-URF/6016T-NTRFThe SuperServer 6016T-URF/6016T-NTRF has a 650 watt redundant power supply con

Strona 68 - 6016T-UF/6016T-NTF

6-10SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual6016T-UF/6016T-NTFThe SuperServer 6016T-UF/6016T-NTF has a single 560 watt p

Strona 69

Chapter 6: Advanced Chassis Setup6-11Figure 6-6. Removing/Replacing the Power Supply

Strona 70

viiTable of ContentsInstalling the Server into a Telco Rack ... 2-72-5 Checking the Serverboa

Strona 71 - Chapter 7

6-12SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualNotes

Strona 72 - 7-2 Main Setup

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTU-F. The AMI ROM BIOS is stored in a Fl

Strona 73

7-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST

Strona 74 - XBOOT Features

Chapter 7: BIOS7-3AMI BIOSVersion• : This item displays the BIOS revision used in your system.Build Date• : This item displays the date when this BI

Strona 75 - Processor and Clock Options

7-4SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and

Strona 76

Chapter 7: BIOS7-5Wait For 'F1' If ErrorThis forces the system to wait until the 'F1' key is pressed if an error occurs. The optio

Strona 77 - XQPI & IMC Confi guration

7-6SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualHardware Prefetcher (Available when supported by the CPU)If set to Enabled, t

Strona 78

Chapter 7: BIOS7-7C1E SupportSelect Enabled to use the feature of Enhanced Halt State. C1E signifi cantly reduces the CPU's power consumption by r

Strona 79

7-8SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualQPI Links SpeedThis feature selects QPI's data transfer speed. The optio

Strona 80

Chapter 7: BIOS7-9Hysteresis Temperature (This feature is available when Closed Loop is enabled.)Temperature Hysteresis is the temperature lag (in deg

Strona 81 - IDE/Floppy Confi guration

viiiSUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual5-8 Connector Defi nitions ...

Strona 82 - XPCI/PnP Confi guration

7-10SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manualproviding the user with greater reliability, security and availability in ne

Strona 83 - XRemote Access Confi guration

Chapter 7: BIOS7-11USB FunctionsThis feature allows the user to decide the number of onboard USB ports to be en-abled. The Options are: Disabled, 2 US

Strona 84 - Hardware Health Monitor

7-12SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualSATA AHCI (Available when the option-AHCI is selected.)Select Enable to enab

Strona 85

Chapter 7: BIOS7-13PCI-E Slot from SXB1/PCI-E Slot from SXB2/PCI-E Slot from SXB3Select Enabled to enable PCI-E SXB1 slot, PCI-E SXB2 slot or PCI-E SX

Strona 86 - XACPI Confi guration

7-14SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualSerial Port ModeThis feature allows the user to set the serial port mode for

Strona 87

Chapter 7: BIOS7-15The options are:The Early Alarm: Select this setting if you want the CPU overheat alarm (includ-• ing the LED and the buzzer) to be

Strona 88 - View BMC System Event Log

7-16SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualUser intervention: No action is required. However, consider checking the CPU

Strona 89 - Set LAN Confi guration

Chapter 7: BIOS7-17High Performance Event TimerSelect Enabled to activate the High Performance Event Timer (HPET) that produces periodic interrupts at

Strona 90 - SET PEF Confi guration

7-18SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualStatus of BMC WorkingThe Baseboard Management Controller (BMC) manages the i

Strona 91 - 7-4 Security Settings

Chapter 7: BIOS7-19XSet LAN Confi gurationSet this feature to confi gure the IPMI LAN adapter with a network address as shown in the following graphics.

Strona 92

Chapter 1 Introduction1-1 OverviewThe SuperServer 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF is a high-end server comprised of two main subsystems: the S

Strona 93 - 7-5 Boot Confi guration

7-20SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualXSET PEF Confi gurationPEF SupportSelect Enabled to enable the function of Pl

Strona 94 - 7-6 Exit Options

Chapter 7: BIOS7-21BMC Watch Dog TimeOut [Min:Sec]This option appears if BMC Watch Dog Timer Action (above) is enabled. This is a timed delay in minut

Strona 95 - BIOS Error Beep Codes

7-22SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualSupervisor Password This item indicates if a Supervisor password has been en

Strona 96

Chapter 7: BIOS7-237-5 Boot Confi gurationUse this feature to confi gure boot settings. XBoot Device PriorityThis feature allows the user to specify the

Strona 97 - Installing Windows

7-24SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual7-6 Exit OptionsSelect the Exit tab from the Setup Utility screen to enter t

Strona 98

A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the

Strona 99 - System Specifi cations

A-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualNotes

Strona 100

Appendix B: Installing WindowsB-1Appendix B Installing Windows After all hardware components have been installed, you must fi rst confi gure Intel South

Strona 101 - Regulatory Compliance

B-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualB-2 Installing the Windows OS for a Non-RAID SystemInsert Microsoft's W

Strona 102

C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessors Single or dual Intel® 5500 Series processors in LGA1366 sockets

Komentarze do niniejszej Instrukcji