SUPERSERVER 6016T-URF SUPERSERVER 6016T-UF SUPERSERVER 6016T-NTRF SUPERSERVER 6016T-NTF SUPER®USER’S MANUAL1.0
1-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 6016T-URF/6016T-UF/60
C-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualExpansion Slots 6016T-URF/6016T-UF: Right side: (optional) 2x Gb
C-3Appendix C: System Specifi cationsOperating Environment Operating Temperature: 10º to 35º C (50º to 95º F) Non-operating Temperature: -40º
C-4SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualNotes
1-3Chapter 1: IntroductionGraphics ControllerThe X8DTU-F features an integrated Matrox G200eW graphics chip, which includes 8 MB of DDR2 memory.Other
1-4SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual6016T-NTRF/6016T-NTF: A riser card (RSC-R1UU-E8PR, optional) on the right sid
1-5Chapter 1: IntroductionFigure 1-1. Intel IOH-36D/ICH10R Chipset: System Block DiagramNote: This is a general block diagram. Please see Chapter 5 f
1-6SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 6016T-
2-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual!!Warnings and Precautions!Choosing a Setup LocationLeave enough clearance in
Chapter 2: Server Installation2-3Allow the hot plug SATA drives and power supply modules to cool before touch-• ing them.Always keep the rack's f
2-4SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual2-4 Installing the System into a RackThis section provides information on in
Chapter 2: Server Installation2-5Installing the Outer RailsBegin by measuring the distance from the front rail to the rear rail of the rack. Attach a
Manual Revision 1.0 Release Date: April 24, 2009The information in this User’s Manual has been carefully reviewed and is believed to be accurate
2-6SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualFigure 2-3. Installing the Server into a RackInstalling the Server into the
Chapter 2: Server Installation2-7Figure 2-4. Installing the Server into a Telco RackInstalling the Server into a Telco RackTo install the 6016T-URF/6
2-8SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual2-5 Checking the Serverboard SetupAfter you install the 6016T-URF/6016T-UF/6
Chapter 2: Server Installation2-9Figure 2-5. Accessing the Inside of the System2-6 Checking the Drive Bay SetupNext, you should check to make sure t
2-10SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualChecking the Airfl owAirfl ow is provided by four sets of 4-cm fans (each set
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the SATA drive ca
3-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualPowerThe main power button is used to apply or remove power from the power su
Chapter 3: System Interface3-3NIC2Indicates network activity on LAN2 when fl ashing.21NIC1Indicates network activity on LAN1 when fl ashing.HDDOn the Su
3-4SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual3-4 Hard Drive Carrier LEDsEach hard drive carrier has two LEDs.Green:• W
Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect
iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It pro-vides information for the inst
4-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual4-2 General Safety PrecautionsFollow these rules to ensure general safety:Ke
Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic discharge (ESD) is generated by two objects with different electrical charges coming into
4-4SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual4-4 Operating PrecautionsCare must be taken to assure that the chassis cover
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install processors and heatsinks
5-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual5-2 Processor and Heatsink InstallationIMPORTANT! Always connect the power c
Chapter 5: Advanced Serverboard Setup5-3After removing the plastic cap, use 1. your thumb and the index fi nger to hold the CPU at the north and south
5-4SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualThermal GreaseCPUPlace the heatsink on top of the 1. CPU so that the four mou
Chapter 5: Advanced Serverboard Setup5-5Unplug the power cord from the power supply.1. Unscrew and remove the heatsink screws in the 1. sequence shown
5-6SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual5-3 Connecting CablesNow that the processors are installed, the next step is
Chapter 5: Advanced Serverboard Setup5-7Figure 5-1. Front Control Panel Header Pins (JF1)See the Connector Defi nitions section in this chapter for det
SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information
5-8SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual5-5 Installing MemoryNote: Check the Supermicro web site for recommended memo
Chapter 5: Advanced Serverboard Setup5-9Figure 5-3. Installing DIMM into SlotPossible System Memory Allocation & AvailabilitySystem Device Size Ph
5-10SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual5-6 Adding PCI CardsPCI Expansion SlotsRiser cards are used to support add-
Chapter 5: Advanced Serverboard Setup5-11Figure 5-4. SUPER X8DTU-F Layout(not drawn to scale)5-7 Serverboard DetailsKB /MSIPMI LANUSB 0/1COM1VGALAN1U
5-12SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualX8DTU-F Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear (Se
Chapter 5: Advanced Serverboard Setup5-135-8 Connector Defi nitionsPower LED The Power LED connection is located on pins 15 and 16 of JF1. Refer to the
5-14SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualNIC1 LEDThe NIC1 (Network Interface Control-ler) LED connection is located o
Chapter 5: Advanced Serverboard Setup5-15Reset Button The Reset Button connection is lo-cated on pins 3 and 4 of JF1. Attach it to the hardware reset
5-16SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualFan HeadersThe X8DTU-F has eight headers, designated Fan1 through Fan8. FAN1
Chapter 5: Advanced Serverboard Setup5-17ATX PS/2 Keyboard and PS/2 Mouse PortsThe ATX PS/2 keyboard and the PS/2 mouse ports are located beside the U
vPrefaceNotes
5-18SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualLAN1/2 (Ethernet Ports)Two Ethernet ports (designated LAN1 and LAN2) are loc
Chapter 5: Advanced Serverboard Setup5-195-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used to c
5-20SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualLAN Enable/Disable Change the setting of jumper JPL1 to enable or disable th
Chapter 5: Advanced Serverboard Setup5-21BMC/PHY ResetJumper JPRST1 allow the user to reset the Winbond WPCM450 BMC (Base-board Management Controller)
5-22SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual5-10 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the
Chapter 5: Advanced Serverboard Setup5-235-11 SATA Port ConnectionsSATA PortsSee the table on the right for pin defi nitions for the onboard SATA port
5-24SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual5-12 Installing SoftwareAfter the hardware has been installed, you should fi
Chapter 5: Advanced Serverboard Setup5-25Supero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports remote management
5-26SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualNote: SD III Software Revision 1.0 can be downloaded from our Web Site at: f
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na
viSUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...
6-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualFigure 6-1. Chassis: Front and Rear ViewsSystem Reset6-2 Control PanelThe co
Chapter 6: Advanced Chassis Setup6-36-3 System FansFour 4-cm heavy duty counter-rotating fans provide the cooling for the SuperServer 6016T-URF/6016T-
6-4SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualFigure 6-2. System Cooling Fans6-4 Drive Bay Installation/RemovalRemoving t
Chapter 6: Advanced Chassis Setup6-5Accessing the Drive BaysHard Drives: Because of their hotswap capability, you do not need to access the inside of
6-6SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualHard Drive InstallationThe hard drives are mounted in drive carriers to simpl
Chapter 6: Advanced Chassis Setup6-7Installing/Removing a Hard DriveTo remove a carrier, push the release button located beside the drive LEDs.1. Swin
6-8SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualDVD-ROM Drive InstallationThe top cover of the chassis must be opened to gain
Chapter 6: Advanced Chassis Setup6-96-5 Power Supply6016T-URF/6016T-NTRFThe SuperServer 6016T-URF/6016T-NTRF has a 650 watt redundant power supply con
6-10SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual6016T-UF/6016T-NTFThe SuperServer 6016T-UF/6016T-NTF has a single 560 watt p
Chapter 6: Advanced Chassis Setup6-11Figure 6-6. Removing/Replacing the Power Supply
viiTable of ContentsInstalling the Server into a Telco Rack ... 2-72-5 Checking the Serverboa
6-12SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualNotes
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTU-F. The AMI ROM BIOS is stored in a Fl
7-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST
Chapter 7: BIOS7-3AMI BIOSVersion• : This item displays the BIOS revision used in your system.Build Date• : This item displays the date when this BI
7-4SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and
Chapter 7: BIOS7-5Wait For 'F1' If ErrorThis forces the system to wait until the 'F1' key is pressed if an error occurs. The optio
7-6SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualHardware Prefetcher (Available when supported by the CPU)If set to Enabled, t
Chapter 7: BIOS7-7C1E SupportSelect Enabled to use the feature of Enhanced Halt State. C1E signifi cantly reduces the CPU's power consumption by r
7-8SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualQPI Links SpeedThis feature selects QPI's data transfer speed. The optio
Chapter 7: BIOS7-9Hysteresis Temperature (This feature is available when Closed Loop is enabled.)Temperature Hysteresis is the temperature lag (in deg
viiiSUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual5-8 Connector Defi nitions ...
7-10SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manualproviding the user with greater reliability, security and availability in ne
Chapter 7: BIOS7-11USB FunctionsThis feature allows the user to decide the number of onboard USB ports to be en-abled. The Options are: Disabled, 2 US
7-12SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualSATA AHCI (Available when the option-AHCI is selected.)Select Enable to enab
Chapter 7: BIOS7-13PCI-E Slot from SXB1/PCI-E Slot from SXB2/PCI-E Slot from SXB3Select Enabled to enable PCI-E SXB1 slot, PCI-E SXB2 slot or PCI-E SX
7-14SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualSerial Port ModeThis feature allows the user to set the serial port mode for
Chapter 7: BIOS7-15The options are:The Early Alarm: Select this setting if you want the CPU overheat alarm (includ-• ing the LED and the buzzer) to be
7-16SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualUser intervention: No action is required. However, consider checking the CPU
Chapter 7: BIOS7-17High Performance Event TimerSelect Enabled to activate the High Performance Event Timer (HPET) that produces periodic interrupts at
7-18SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualStatus of BMC WorkingThe Baseboard Management Controller (BMC) manages the i
Chapter 7: BIOS7-19XSet LAN Confi gurationSet this feature to confi gure the IPMI LAN adapter with a network address as shown in the following graphics.
Chapter 1 Introduction1-1 OverviewThe SuperServer 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF is a high-end server comprised of two main subsystems: the S
7-20SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualXSET PEF Confi gurationPEF SupportSelect Enabled to enable the function of Pl
Chapter 7: BIOS7-21BMC Watch Dog TimeOut [Min:Sec]This option appears if BMC Watch Dog Timer Action (above) is enabled. This is a timed delay in minut
7-22SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualSupervisor Password This item indicates if a Supervisor password has been en
Chapter 7: BIOS7-237-5 Boot Confi gurationUse this feature to confi gure boot settings. XBoot Device PriorityThis feature allows the user to specify the
7-24SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual7-6 Exit OptionsSelect the Exit tab from the Setup Utility screen to enter t
A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the
A-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualNotes
Appendix B: Installing WindowsB-1Appendix B Installing Windows After all hardware components have been installed, you must fi rst confi gure Intel South
B-2SUPERSERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's ManualB-2 Installing the Windows OS for a Non-RAID SystemInsert Microsoft's W
C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessors Single or dual Intel® 5500 Series processors in LGA1366 sockets
Komentarze do niniejszej Instrukcji