SUPERSERVER6028R-WTR6028R-WTRT® SUPERUSER’S MANUALRevision 1.0
SUPERSERVER 6028R-WTR(T) USER'S MANUALxNotes
7-14SUPERSERVER 6028R-WTR(T) USER'S MANUALSATA Confi gurationWhen this submenu is selected, the AMI BIOS automatically detects the presence of ID
Chapter 7: BIOS7-15SATA RAID Option ROM/UEFI DriverSelect Enabled to boot the system from a SATA RAID device or a UEFI (Unifi ed Extensible Firmware In
7-16SUPERSERVER 6028R-WTR(T) USER'S MANUALASPM SupportThis feature allows the user to set the Active State Power Management (ASPM) level for a PC
Chapter 7: BIOS7-17Super IO Confi gurationSuper IO ChipDisplays the Super IO chip type.COM 1 Confi gurationSerial PortSelect Enabled to enable a seria
7-18SUPERSERVER 6028R-WTR(T) USER'S MANUALSOL (Serial_Over_LAN) Device ModeUse this feature to select the desired mode for the SOL port. The opti
Chapter 7: BIOS7-19Data BitsUse this feature to set the data transmission size for Console Redirection. The options are 7 and 8 (Bits).ParityA parity
7-20SUPERSERVER 6028R-WTR(T) USER'S MANUALPutty KeypadUse this feature to select function key and keypad setting on Putty. The options are VT100,
Chapter 7: BIOS7-21Flow ControlThis feature allows the user to set the fl ow control for Console Redirection to prevent data loss caused by buffer over
7-22SUPERSERVER 6028R-WTR(T) USER'S MANUALHigh Precision Event TimerSelect Enabled to activate the High Precision Event Timer (HPET) that produce
Chapter 7: BIOS7-23Intel TXT(LT-SX) Confi gurationThis feature indicates if the following hardware components support the Intel TXT (Trusted Execution
Chapter 1 Introduction1-1 OverviewThe SuperServer 6028R-WTR(T) is a high-end server comprised of two main subsystems: the SC815TS-R740WBP 2U chassis a
7-24SUPERSERVER 6028R-WTR(T) USER'S MANUALRuntime Error Logging SupportChange this item to enable or disable runtime error logging. The options a
Chapter 7: BIOS7-257-5 IPMIUse this menu to confi gure Intelligent Platform Management Interface (IPMI) settings.System Event LogEnabling/Disabling Op
7-26SUPERSERVER 6028R-WTR(T) USER'S MANUALWhen SEL is FullThis feature allows the user to decide what the BIOS should do when the system event lo
Chapter 7: BIOS7-277-6 BootThis menu allows the user to confi gure the following boot settings for the system.Set Boot Priorities1st Boot Device/2nd Bo
7-28SUPERSERVER 6028R-WTR(T) USER'S MANUALUSB Hard Disk Drive BBS PrioritiesThis submenu allows the user to specify the boot priority sequence o
Chapter 7: BIOS7-29Password CheckThis item allows you to decide when the system should check for a password after it has been entered. Select Setup fo
7-30SUPERSERVER 6028R-WTR(T) USER'S MANUALSave Changes and ResetWhen you have completed the system confi guration changes, select this option to s
Chapter 7: BIOS7-31Boot OverrideThis feature allows the user to override the Boot Option Priorities setting in the Boot menu, and instead immediately
7-32SUPERSERVER 6028R-WTR(T) USER'S MANUALNotes
A-1Appendix A: BIOS POST Error CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed at each system
1-2SUPERSERVER 6028R-WTR(T) USER'S MANUAL1-2 Serverboard FeaturesThe SuperServer 6028R-WTR(T) is built around the X10DRW-i(T), a dual processor s
A-2SUPERSERVER 6028R-WTR(T) USER'S MANUALNotes
B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessorsSingle or dual Intel® Xeon E5-2600v3 Series processors.Note: If using a
B-2SUPERSERVER 6027R-73DARF User's ManualWeight57 lbs. (25.9 kg.)System CoolingThree 8-cm system cooling fansNote: The system cooling fans are re
B-3Appendix B: System Specifi cationsNotes
B-4SUPERSERVER 6027R-73DARF User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life
1-3Chapter 1: IntroductionRear I/O PortsPorts on the I/O backplane includes a VGA port, four USB 2.0 ports, two gigabit (6028R-WTR) or 10-gigabit (602
1-4SUPERSERVER 6028R-WTR(T) USER'S MANUAL1-6 Advanced Power ManagementIntel® Intelligent Power Node Manager (IPNM)The Intel® Intelligent Power N
1-5Chapter 1: IntroductionFigure 1-1. Intel PCH-C612 Chipset: System Block DiagramNote: This is a general block diagram. Please see Chapter 5 for deta
1-6SUPERSERVER 6028R-WTR(T) USER'S MANUAL1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 6028R-
2-2SUPERSERVER 6027R-73DARF User's ManualChoosing a Setup Location• Leave enough clearance in front of the rack to enable you to open the front d
Chapter 2: Server Installation2-3Rack Mounting Considerations Warning! To prevent bodily injury when mounting or servicing this unit in a rack, you mu
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu
2-4SUPERSERVER 6027R-73DARF User's Manual2-4 Installing the System into a RackThis section provides information on installing the SC815 chassis
Chapter 2: Server Installation2-5Figure 2-1: Separating the Rack Rails Separating the Inner and Outer Rails1. Locate the rail assembly in the chassis
2-6SUPERSERVER 6027R-73DARF User's ManualInstalling the Chassis into a Rack1. Extend the outer rails as illustrated above. 2. Align the inner r
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the drive carrier
SUPERSERVER 6027R-73DARF User's Manual3-213-3 Control Panel LEDsThe control panel located on the front of the chassis has several LEDs. These LE
Chapter 3: System Interface3-32NIC2Indicates network activity on the LAN2 port when fl ashing.HDDOn the SuperServer 6028R-WTR(T), this LED indicates ha
SUPERSERVER 6027R-73DARF User's Manual3-4Notes
4-1Chapter 4: Warning Statements for AC SystemsChapter 4 Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe f
4-2SUPERSERVER 6028R-WTR(T) USER'S MANUALWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situat
4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에
iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta
4-4SUPERSERVER 6028R-WTR(T) USER'S MANUALInstallation Instructions Warning!Read the installation instructions before connecting the system to the
4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over
4-6SUPERSERVER 6028R-WTR(T) USER'S MANUALPower Disconnection Warning Warning!The system must be disconnected from all sources of power and the po
4-7Chapter 4: Warning Statements for AC SystemsWarnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt sein, das von
4-8SUPERSERVER 6028R-WTR(T) USER'S MANUALEquipment Installation Warning!Only trained and qualifi ed personnel should be allowed to install, replac
4-9Chapter 4: Warning Statements for AC SystemsRestricted Area Warning!This unit is intended for installation in restricted access areas. A restricted
4-10SUPERSERVER 6028R-WTR(T) USER'S MANUALBattery Handling Warning!There is the danger of explosion if the battery is replaced incorrectly. Repla
4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur
4-12SUPERSERVER 6028R-WTR(T) USER'S MANUALRedundant Power Supplies Warning!This unit might have more than one power supply connection. All connec
4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltage Warning!Hazardous voltage or energy is present on the backplane when the system is o
SUPERSERVER 6028R-WTR(T) USER'S MANUALivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X10DRW-i(T) serverboa
4-14SUPERSERVER 6028R-WTR(T) USER'S MANUALComply with Local and National Electrical Codes Warning!Installation of the equipment must comply with
4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national
4-16SUPERSERVER 6028R-WTR(T) USER'S MANUALWarnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen
4-17Chapter 4: Warning Statements for AC Systems!הרהזא יקלח תא םיריסמ רשאכ שי .םידבוע ןיידע םיררוואמהו ןכתי ,זראמהמ ררוואמה קיחרהללררוואמה ךותב םיחתפ
4-18SUPERSERVER 6028R-WTR(T) USER'S MANUALPower Cable and AC Adapter Warning!When installing the product, use the provided or designated connect
4-19Chapter 4: Warning Statements for AC Systems¡Advertencia! Al instalar el producto, utilice los cables de conexión previstos o designados, los cabl
4-20SUPERSERVER 6028R-WTR(T) USER'S MANUALWaarschuwing Bij het installeren van het product, gebruik de meegeleverde of aangewezen kabels, stroomk
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to connect the data and power cable
5-2SUPERSERVER 6028R-WTR(T) USER'S MANUAL5-2 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to th
Chapter 5: Advanced Serverboard Setup5-3Figure 5-1. Control Panel Header PinsPower ButtonOH/Fan Fail/PWR Fail LED)1NIC1 Link LEDReset Button2Power Fai
NotesPrefacev
5-4SUPERSERVER 6028R-WTR(T) USER'S MANUAL5-3 Rear I/O PortsThe I/O ports are in conformance with the PC 99 specifi cation. See Figure 5-2 below f
Chapter 5: Advanced Serverboard Setup5-51. There are two levers on the LGA2011 socket. First press and release the load lever labeled 'Open 1st&
5-6SUPERSERVER 6028R-WTR(T) USER'S MANUAL3. With the lever labeled 'Close 1st' fully retracted, gently push down on the 'Open 1st
Chapter 5: Advanced Serverboard Setup5-7Caution: You can only install the CPU to the socket in one direction. Make sure that the CPU is properly inse
5-8SUPERSERVER 6028R-WTR(T) USER'S MANUALInstalling a Passive CPU Heatsink1. Do not apply any thermal grease to the two heatsinks or the CPU die
Chapter 5: Advanced Serverboard Setup5-9Removing the HeatsinkWarning: We do not recommend that the CPU or the heatsink be removed. However, if you do
5-10SUPERSERVER 6028R-WTR(T) USER'S MANUAL5-5 Installing MemoryCaution! Exercise extreme care when installing or removing DIMM modules to preven
Chapter 5: Advanced Serverboard Setup5-11DIMM Module Population TableFollow the tables below when installing memory.Processors and their Corresponding
5-12SUPERSERVER 6028R-WTR(T) USER'S MANUALPopulating RDIMM/LRDIMM Memory Modules Intel E5-2600v3 Series Processor Memory SupportType Ranks Per DI
Chapter 5: Advanced Serverboard Setup5-135-6 Adding PCI Add-On CardsThe 6028R-WTR(T) can accommodate up to six low-profi le add-on (expansion) cards.I
viTable of ContentsChapter 1 Introduction1-1 Overview ...
5-14SUPERSERVER 6028R-WTR(T) USER'S MANUALFigure 5-5. X10DRW-i(T) Layout5-7 Serverboard DetailsS-SGPIOI-SGPIO2I-SGPIO1JIPMB1SAN MACIPMI CODEJBAT1
Chapter 5: Advanced Serverboard Setup5-15X10DRW-i(T) JumpersJumper Description Default SettingJBT1 Clear CMOS See Chapter 3JI2C1/JI2C2 SMB to PCI-E sl
5-16SUPERSERVER 6028R-WTR(T) USER'S MANUALConnectors DescriptionS-SGPIO Seria_Link General-Purpose (SGPIO) I/O header for S-SATA connections 0-3S
Chapter 5: Advanced Serverboard Setup5-175-8 Connector Defi nitions Power Connectors A 24-pin main power supply connector (JPWR1), and two 8-pin CPU po
5-18SUPERSERVER 6028R-WTR(T) USER'S MANUALNIC1/NIC2 LED IndicatorsThe NIC (Network Interface Controller) LED connection for LAN Port 1 is located
Chapter 5: Advanced Serverboard Setup5-19Power LED The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table on the right for p
5-20SUPERSERVER 6028R-WTR(T) USER'S MANUALUniversal Serial Bus (USB)Four USB 3.0 ports (USB 0/1, USB 2/3) are located on the I/O backpanel. In ad
Chapter 5: Advanced Serverboard Setup5-21Unit Identifi er Switch/UID LED IndicatorA Unit Identifi er (UID) switch is located on the I/O backplane, and t
5-22SUPERSERVER 6028R-WTR(T) USER'S MANUALS-SGPIO and I-SGPIO 1/2 HeadersThree SGPIO (Serial Link General Purpose Input/Output) headers are locat
Chapter 5: Advanced Serverboard Setup5-235-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used to c
viiChapter 3 System Interface3-1 Overview ... 3-
5-24SUPERSERVER 6028R-WTR(T) USER'S MANUALWatch Dog Enable/DisableJumper Settings (JWD1)Jumper Setting Defi nitionPins 1-2 ResetPins 2-3 NMIOp
Chapter 5: Advanced Serverboard Setup5-25I2C to PCI-EJumper SettingJumper Setting Defi nitionPins 1-2 EnabledPins 2-3 Disabled (Default)ME Mode Sel
5-26SUPERSERVER 6028R-WTR(T) USER'S MANUALIPMI Dedicated LAN LEDsIn addition to LAN 1/LAN 2, an IPMI- dedicated LAN is located on the I/O Backpla
Chapter 5: Advanced Serverboard Setup5-27Onboard Power LED An Onboard Power LED is located at LED2 on the serverboard. When this LED is on, the system
5-28SUPERSERVER 6028R-WTR(T) USER'S MANUALFigure 5-6. Driver/Tool Installation Display Screen5-12 Installing SoftwareThe Supermicro ftp site cont
Chapter 5: Advanced Serverboard Setup5-29Note: Click the icons showing a hand writing on paper to view the readme fi les for each item. Click the compu
5-30SUPERSERVER 6028R-WTR(T) USER'S MANUALFigure 5-8. SuperDoctor 5 Interface Display Screen (Remote Control)Note: The SuperDoctor 5 program and
Chapter 5: Advanced Serverboard Setup5-315-13 Serverboard BatteryCaution: There is a danger of explosion if the onboard battery is installed upside do
5-32SUPERSERVER 6028R-WTR(T) USER'S MANUALNotes
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform maintenan
viiiSUPERSERVER 6028R-WTR(T) USER'S MANUAL5-4 Installing the Processor and Heatsink ...
6-2SUPERSERVER 6027R-73DARF User's Manual6-2 Control PanelThe control panel (located on the front of the chassis) must be connected to the JF1 co
Chapter 6: Advanced Chassis Setup6-3The fans in the system are redundant, hot-plug.Replacing System FansRemoving a Fan1. Remove the chassis cover.2.
6-4SUPERSERVER 6027R-73DARF User's Manual6-4 Drive Bay Installation/RemovalAccessing the Drive BaysSAS/SATA Drives: You do not need to access th
Chapter 6: Advanced Chassis Setup6-5Figure 6-3. Removing a Drive CarrierRelease ButtonHandleCaution: Regardless of how many hard drives are installed,
6-6SUPERSERVER 6027R-73DARF User's ManualDVD-ROM Installation (Optional)The top cover of the chassis must be opened to gain full access to the DV
Chapter 6: Advanced Chassis Setup6-76-5 Power SupplyThe SuperServer 6028R-WTR(T) has a 740 Watt redundant power supply consisting of two power modules
6-8SUPERSERVER 6027R-73DARF User's ManualNotes
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup utility for the X10DRW-i(T) It also provides the instruct
7-2SUPERSERVER 6028R-WTR(T) USER'S MANUALHow To Change the Confi guration DataThe confi guration data that determines the system parameters may be
Chapter 7: BIOS7-3Memory InformationTotal MemoryThis displays the amount of memory that is available in the system.7-3 Advanced Setup Confi gurations
ixTable of ContentsChapter 7 BIOS 7-1 Introduction ...
7-4SUPERSERVER 6028R-WTR(T) USER'S MANUALBootup Num-LockUse this feature to set the Power-on state for the Numlock key. The options are Off and O
Chapter 7: BIOS7-5CPU Confi gurationThis submenu displays the information of the CPU as detected by the BIOS. It also allows the user to confi gure the
7-6SUPERSERVER 6028R-WTR(T) USER'S MANUALRTID (Record Types IDs)This feature displays the total number of Record Type IDs for local and remote po
Chapter 7: BIOS7-7DCU Streamer Prefetcher (Available when supported by the CPU)Select Enabled to support Data Cache Unite (DCU) prefetch to speed up d
7-8SUPERSERVER 6028R-WTR(T) USER'S MANUALC1E Support (Available when Power Technology is set to Custom)Select Enabled to enable Enhanced C1 Power
Chapter 7: BIOS7-9Long Duration MaintainedThis item displays the period of time (in seconds) during which long duration power is maintained. The defau
7-10SUPERSERVER 6028R-WTR(T) USER'S MANUALIntel® I/OATSelect Enabled to enable Intel I/OAT (I/O Acceleration Technology), which will significantl
Chapter 7: BIOS7-11QPI (Quick Path Interconnect) Link Speed ModeUse this feature to select data transfer speed for QPI Link connections. The options a
7-12SUPERSERVER 6028R-WTR(T) USER'S MANUALChannel InterleavingThis feature selects from the different channel interleaving methods. The options a
Chapter 7: BIOS7-13South BridgeThis feature allows the user to confi gure the settings for the Intel PCH chip.PCH InformationThis feature displays the
Komentarze do niniejszej Instrukcji