SUPERSERVER 6028R-T/TT Manual
2-5 Installing the System into a Rack
This section provides information on installing the SuperServer 6028R-T/TT into a
rack unit. If the 6028R-T/TT has already been mounted into a rack, you can skip
ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which
may mean the assembly procedure will differ slightly. The following is a guideline
for installing the 6028R-T/TT into a rack with the rack rails provided. You should
also refer to the installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies with the SuperServer 6028R-T/
TT. Each of these assemblies consist of three sections: an inner xed chassis rail
that secures to the 6028R-T/TT (A) and an outer xed rack rail that secures directly
to the rack itself (B). A sliding rail guide sandwiched between the two should remain
attached to the xed rack rail (see Figure 2-1). The A and B rails must be detached
from each other to install.
To remove the xed chassis rail (A), pull it out as far as possible - you should hear
a "click" sound as a locking tab emerges from inside the rail assembly and locks
the inner rail. Then depress the locking tab to pull the inner rail completely out. Do
this for both the left and right side rack rail assemblies.
Figure 2-1. Identifying the Sections of the Rack Rails