7-14SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALSATA Confi gurationWhen this submenu is selected, the AMI BIOS automatically detects the presence o

Strona 4

Chapter 7: BIOS7-15RAID ModeThe following items are displayed when RAID Mode is selected:Port 0~5 Hot PlugSelect Enabled to enable hot-plug support fo

Strona 5

7-16SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALASPM SupportThis feature allows the user to set the Active State Power Management (ASPM) level for

Strona 6 - Table of Contents

Chapter 7: BIOS7-17Super IO Confi gurationSuper IO Chip: This item displays the Super IO chip used in the motherboard.Serial Port 1 Confi gurationSeri

Strona 7 - Chapter 4 System Safety

7-18SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALDevice ModeUse this feature to select the desired mode for a serial port specifi ed. The options ar

Strona 8 - Chapter 7 BIOS

Chapter 7: BIOS7-19Data BitsUse this feature to set the data transmission size for Console Redirection. The options are 7 Bits and 8 Bits. ParityA par

Strona 9

7-20SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALPutty KeyPadThis feature selects Function Keys and KeyPad settings for Putty, which is a terminal e

Strona 10

Chapter 7: BIOS7-21Flow ControlThis feature allows the user to set the fl ow control for Console Redirection to prevent data loss caused by buffer over

Strona 11 - Chapter 1

7-22SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALTrusted Computing (Available when a TPM device is detected by the BIOS)Confi gurationTPM SupportSel

Strona 12 - 1-2 Serverboard Features

Chapter 7: BIOS7-23CPU: TXT (Trusted Execution Technology) FeatureChipset: TXT (Trusted Execution Technology) FeatureIntel TXT (LT-SX) Confi gurationTh

Strona 13 - 1-3 Server Chassis Features

Chapter 1 Introduction1-1 OverviewThe SuperServer 8047R-TRF+/7RFT+ is a high-end server comprised of two main subsystems: the SC748TQ-R1K43BP 4U serve

Strona 14

7-24SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL7-4 Event LogsUse this feature to confi gure Event Log settings.Change SMBIOS Event Log SettingsThi

Strona 15 - Manageability Engine (ME)

Chapter 7: BIOS7-25SMBIOS Event Log Standard SettingsLog System Boot EventSelect Enabled to log system boot events. The options are Disabled and Enabl

Strona 16 - System Block Diagram

7-26SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL7-5 IPMIUse this feature to confi gure Intelligent Platform Management Interface (IPMI) settings.

Strona 17 - 1-5 Contacting Supermicro

Chapter 7: BIOS7-27BMC Network Confi gurationLAN Channel 1/LAN Channel 2:This feature allows the user to confi gure the settings for LAN1/LAN 2 Ports.U

Strona 18

7-28SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL7-6 BootThis submenu allows the user to confi gure the following boot settings for the system.Boot

Strona 19 - Server Installation

Chapter 7: BIOS7-297-8 Save & ExitThis submenu allows the user to confi gure the Save and Exit settings for the system.Discard Changes and Exit Se

Strona 20 - 2-4 Cautions!

7-30SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALSave as User DefaultsSelect this feature and press <Enter> to save the current settings as th

Strona 21 - Rack Mounting Considerations

A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the

Strona 22 - Removing the Feet

A-2SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALNotes

Strona 23 - Chassis Cover Lock

B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessorsQuad Intel E5-4600 Series series (Socket R-LGA 2011 type) processorsNote

Strona 24

1-2SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL• If you have any questions, please contact our support team at [email protected] Serverboar

Strona 25

B-2SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALExpansion SlotsFour PCI low-profi le expansion card slots are available in the rear of the chassis fo

Strona 26

B-3Appendix B: System Specifi cationsRegulatory ComplianceElectromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A

Strona 27

B-4SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL(continued from front)The products sold by Supermicro are not intended for and will not be used in l

Strona 28

Chapter 1: Introduction1-3SAS (8047R-7RFT+ Server Only)A LSI® 2208 SAS controller is integrated into the serverboard to provide an eight port SAS (Ser

Strona 29

1-4SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALHard Drive SubsystemThe SC748TQ-R1K43BP chassis was designed to support fi ve 3.5" hot-swap SATA

Strona 30

Chapter 1: Introduction1-5Cooling SystemThe SC748TQ-R1K43BP chassis has an innovative cooling design that includes three 8-cm and three 9.2-cm hot-plu

Strona 31

1-6SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFigure 1-1. Intel C602 Chipset: System Block DiagramNote: This is a general block diagram. Please se

Strona 32

Chapter 1: Introduction1-71-5 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408

Strona 33 - System Interface

1-8SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALNotes

Strona 34 - 3-2 Control Panel Buttons

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 8047R-

Strona 35 - Power Fail LED

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu

Strona 36 - 3-4 Drive Carrier LEDs

2-2SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL• This product is for installation only in a Restricted Access Location (dedicated equipment rooms,

Strona 37 - System Safety

Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am

Strona 38

2-4SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL2-5 Installing the System into a RackThis section provides information on installing the SC748 chas

Strona 39 - 4-3 ESD Precautions

Chapter 2: Server Installation2-5Figure 2-1: Remove the Chassis Cover and FeetChassis FeetChassis CoverChassis Cover Lock

Strona 40 - 4-4 Operating Precautions

2-6SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFigure 2-2: Identifying the Inner Rails and Chassis HandlesChassis HandleInner RailsChassis HandleSc

Strona 41 - Advanced Serverboard Setup

Chapter 2: Server Installation2-7Figure 2-4: Installing the Inner Rack Rails 2. Align the chassis handle with the front of the chassis and secure wit

Strona 42 - • Control Panel cable (JF1)

2-8SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALInstalling the Outer Rails to the Rack (Figure 2-5)1. Attach the front and rear short brackets to t

Strona 43 - 5-3 I/O Ports

Chapter 2: Server Installation2-9Installing the Chassis into a Rack1. Confi rm that chassis includes the inner rails and the outer rails. 2. Line chas

Strona 44 - WARNING!

2-10SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFigure 6-7: Installing the Chassis into a Rack3. Slide the chassis rails into the rack rails, keep

Strona 45

Chapter 2: Server Installation2-112-6 Tower Confi guration InstructionsThe SC748 chassis is shipped with the chassis cover and feet pre-installed. To u

Strona 46

iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta

Strona 47 - OPEN 1st

2-12SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL2-7 Checking the Serverboard SetupAfter you setup the 8047R-TRF+/7RFT+ (in the rack or tower confi

Strona 48

Chapter 2: Server Installation2-13Figure 5-1: Removing the Chassis CoverRemove Screws14131213Checking the Components and Setup1. You may have one or

Strona 49

2-14SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL2-8 Checking the Drive Bay SetupNext, you should check to make sure the peripheral drives and the

Strona 50 - 5-5 Installing Memory

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the drive carrier

Strona 51 - CPUs+DIMMs

SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL3-23-3 Control Panel LEDsThe control panel located on the front of the chassis has several LEDs. These

Strona 52 - Populating Memory Modules

Chapter 3: System Interface3-312Universal Information LEDWhen this LED blinks red quickly, it indicates a fan failure and when blinking red slowly a p

Strona 53

SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL3-43-4 Drive Carrier LEDsEach drive carrier has two LEDs:SATA Drives• Green: When illuminated, the gre

Strona 54 - X9QR7-TF+/X9QRi-F+

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect

Strona 55 - LED Description State Status

SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL4-2• Serverboard Battery: CAUTION - There is a danger of explosion if the onboard CR2032 battery is ins

Strona 56 - 5-8 Connector Defi nitions

Chapter 4: System Safety4-34-3 ESD Precautions!Electrostatic discharge (ESD) is generated by two objects with different electrical charges coming into

Strona 57

SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALivChapter 6: Advanced Chassis SetupRefer to Chapter 6 for detailed information on the SC748TQ-R1K43BP s

Strona 58

SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the Su

Strona 59

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X9QRi-F+/X9QR7-TF+ s

Strona 60

5-2SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL5-2 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables t

Strona 61

Chapter 5: Advanced Serverboard Setup5-35-3 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 below

Strona 62 - 5-10 Jumper Settings

5-4SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL5-4 Installing the Processor and HeatsinkCaution! Avoid placing direct pressure to the top of the p

Strona 63

Chapter 5: Advanced Serverboard Setup5-52. Press the second load lever labeled 'Close 1st' to release the load plate that covers the CPU so

Strona 64 - BMC: Normal

5-6SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL5. Use your thumb and index fi nger to hold the CPU on its edges. Align the CPU keys, which are semi

Strona 65 - 5-12 SAS/SATA Ports

Chapter 5: Advanced Serverboard Setup5-77. With the CPU inside the socket, inspect the four corners of the CPU to make sure that the CPU is properly

Strona 66 - 5-13 Installing Software

5-8SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALInstalling a Passive CPU Heatsink1. Do not apply any thermal grease to the heatsink or the CPU die

Strona 67 - Supero Doctor III

Chapter 5: Advanced Serverboard Setup5-9OPEN 1stLoosen screws in sequence as shown.Screw#2MotherboardScrew#1Screw#3Removing the HeatsinkCaution: We do

Strona 69 - Advanced Chassis Setup

5-10SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL5-5 Installing MemoryCaution! Exercise extreme care when installing or removing DIMM modules to pre

Strona 70 - 6-2 Control Panel

Chapter 5: Advanced Serverboard Setup5-11Processor & Memory Module Population Confi gurationFor memory to work properly, follow the tables below fo

Strona 71 - Tower or Rack Confi guration

5-12SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALPopulating Memory ModulesIntel E5-4600 Series Processor UDIMM Memory SupportRanks Per DIMM & Da

Strona 72

Chapter 5: Advanced Serverboard Setup5-135-6 Adding PCI-E Add-On CardsThe SC748TQ-R1K43BP chassis can accommodate all the card slots of the X9QRi-F+/

Strona 73

5-14SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFigure 5-4. X9QRi-F+/X9QR7-TF+ Layout5-7 Serverboard DetailsJPW1JPI2C1JP5JP4USB6/7JLPC1JD1JF1JPW5JP

Strona 74

Chapter 5: Advanced Serverboard Setup5-15X9QRi-F+/X9QR7-TF+ Quick Reference Jumper Description Default SettingJBT1 Clear CMOS See Section 5-9JPB1 BMC

Strona 75

5-16SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALReset ButtonPins 3 and 4 of JF1 attaches to the reset button on the computer chassis. See the table

Strona 76

Chapter 5: Advanced Serverboard Setup5-17Overheat/Fan/Pwr Fail/UID LEDConnect an LED to pins 7 and 8 of JF1 to use the Overheat/Fan Fail/Power Fail/UI

Strona 77

5-18SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFan HeadersThere are eight fan headers on the serverboard, all of which are 4-pin fans. However, pi

Strona 78 - 6-4 Installing Hard Drives

Chapter 5: Advanced Serverboard Setup5-19Serial PortsCOM1 is located on the rear I/O panel. COM2, located close to PCI-E Slot2, provides front access

Strona 79

viTable of ContentsChapter 1 Introduction1-1 Overview ...

Strona 80

5-20SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALT-SGPIO 1/2 HeadersTwo SGPIO (Serial-Link General Purpose Input/Output) headers are located on the

Strona 81

Chapter 5: Advanced Serverboard Setup5-21Universal Serial Bus (USB)Four Universal Serial Bus ports (USB0/1, USB2/3) are located on the I/O back panel.

Strona 82

5-22SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL5-10 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can b

Strona 83 - 6-6 System Fans

Chapter 5: Advanced Serverboard Setup5-23VGA Enable/DisableJPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and 2

Strona 84 - Replacing a Rear Chassis Fan

5-24SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL5-11 Onboard IndicatorsIPMI Dedicated LAN LEDsIn addition to LAN 1/LAN 2, an IPMI Dedicated LAN is

Strona 85 - 6-7 Power Supply

Chapter 5: Advanced Serverboard Setup5-255-12 SAS/SATA PortsSATA PortsThere are no jumpers to confi gure the onboard SATA ports. These ports are suppo

Strona 86

5-26SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL5-13 Installing SoftwareAfter the hardware has been installed, you should fi rst install the operati

Strona 87 - Chapter 7

Chapter 5: Advanced Serverboard Setup5-27Supero Doctor IIIThe SuperDoctor® III program is a Web base management tool that supports remote management c

Strona 88 - 7-3 Advanced Settings Menu

5-28SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALNote: The SuperDoctor III program and User’s Manual can be downloaded from the Supermicro web site

Strona 89

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform maintenan

Strona 90 - CPU Confi guration

viiReliable Ground ... 2-32-5 Installing the System into a Rack

Strona 91

6-2SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFigure 6-1. Front and Rear Chassis Views6-2 Control PanelThe control panel (located on the front of

Strona 92

Chapter 6: Advanced Chassis Setup6-36-3 Confi guring the Storage ModuleThis section covers confi guring the storage module for the SC748 chassis. The st

Strona 93

6-4SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFigure 6-4: Chassis Storage ModuleRotating the Storage Module for Rack Mounting1. Open the chassis

Strona 94 - North Bridge

Chapter 6: Advanced Chassis Setup6-5Storage Module Release LeverStorage ModuleFigure 6-5: Remove the Storage ModuleAdding Drives to the Storage Module

Strona 95

6-6SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALInstalling Hard Drives into the Drive Tray1. Open the chassis cover.2. Locate the drive tray you w

Strona 96 - QPI Confi guration

Chapter 6: Advanced Chassis Setup6-7Figure 6-7: Add a Hard Drive to the Drive TrayHard DriveHard Drive TrayAdding Peripheral Drives (DVD-ROM, CD-ROM,

Strona 97 - DIMM Information

6-8SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALHard Drive RailsHard Drive TrayFigure 6-8: Add Hard Drive Rails to the DVD-ROM DriveAdding Five Hard

Strona 98

Chapter 6: Advanced Chassis Setup6-94. Install all six storage module rails onto the mobile rack. Each rail requires two screws. Make sure the arrow

Strona 99 - South Bridge Confi guration

6-10SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL6-4 Installing Hard DrivesThe drives are mounted in drive carriers to simplify their installation

Strona 100 - SATA Confi guration

Chapter 6: Advanced Chassis Setup6-115. Secure the hard drive to the tray using four screws (Figure 6-13).Figure 6-12: Removing the Dummy Drive TrayD

Strona 101 - PCIe/PCI/PnP Confi guration

viii5-5 Installing Memory ... 5-10Memory Support ...

Strona 102

6-12SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALAdd-on Card/Expansion Slot SetupAfter motherboard installation, install add-on cards to the chassis

Strona 103 - Serial Port 1 Confi guration

Chapter 6: Advanced Chassis Setup6-134. Remove the screw holding the bracket in place and pull the bracket from the chassis (Figure 6-15).5. Install

Strona 104 - Console Redirection Settings

6-14SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL6-5 Installing the Air ShroudAir shrouds concentrate airfl ow to maximize fan effi ciency. The SC748

Strona 105

Chapter 6: Advanced Chassis Setup6-156-6 System FansSix heavy duty fans provide cooling for the chassis. Three fans are located in the front of the ch

Strona 106

6-16SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFigure 6-19: Rear Chassis FansReplacing a Rear Chassis FanRear Fan Replacement Procedure (Figure 6-

Strona 107 - ACPI Settings

Chapter 6: Advanced Chassis Setup6-176-7 Power Supply Depending on your chassis model, the SC748 Chassis has a 1400 Watt (redundant) power supply. Thi

Strona 108

6-18SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFigure 6-20: Removing a Power SupplyPress the Release Button1213Pull the Drive OutUsing the Handle

Strona 109 - ME Subsystem

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the SuperServer 8047R-TRF+/7RFT+. The 16 MB SPI

Strona 110 - 7-4 Event Logs

7-2SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALSystem TimeThis item displays the system time in HH:MM:SS format (e.g. 15:32:52).Supermicro X9QR7-TF

Strona 111

Chapter 7: BIOS7-3Interrupt 19 CaptureInterrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Immediate,

Strona 112 - 7-5 IPMI

7-6 Boot ... 7-287-7 Security ...

Strona 113 - BMC Network Confi guration

7-4SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALCPU Confi gurationThis submenu displays the information of the CPU as detected by the BIOS. It also

Strona 114 - 7-7 Security

Chapter 7: BIOS7-5RTID (Record Types IDs)This feature displays the total number of Record Type IDs for local and remote pools. The options are Optimal

Strona 115 - 7-8 Save & Exit

7-6SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALDCU Streamer Prefetcher (Available when supported by the CPU)Select Enabled to support Data Cache Un

Strona 116

Chapter 7: BIOS7-7P-STATE CoordinationThis feature selects the type of coordination for the P-State of the processor. P-State is a processor operatio

Strona 117 - BIOS Error Beep Codes

7-8SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALLong Duration Power LimitThis item displays the power limit (in watts) set by the user during which

Strona 118

Chapter 7: BIOS7-9Data Direct I/OSelect Enabled to enable Intel I/OAT (I/O Acceleration Technology), which signifi cantly reduces CPU overhead by lever

Strona 119 - System Specifi cations

7-10SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALCPU 1 PCIe Slot 3 Link SpeedSelect GEN1 to enable PCI-Exp Generation 1 support for Slot 3. Select G

Strona 120

Chapter 7: BIOS7-11DIMM Confi gurationThis section displays the following DIMM information.Current Memory ModeThis item displays the current memory mo

Strona 121 - Regulatory Compliance

7-12SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALDDR SpeedUse this feature to force a DDR3 memory module to run at a frequency other than what is sp

Strona 122

Chapter 7: BIOS7-13Thermal ThrottlingThrottling improves reliability and reduces power consumption in the processor via automatic voltage control duri